AprilAire E100 vs Santa Fe Ultra V100: cabinet fit and ventilation layout

Both list 100 pints at 80°F/60% RH. Compare the much different installed footprint, ventilation ports, filter access and electrical rating conditions.

Checked Oct 12, 2026 · Exact base models identified below

The useful difference

With an 18-inch cabinet-height limit, rule out the 24-inch V100; the 15-inch E100 remains a candidate. If the taller body and ventilation layout fit, compare both models’ certified whole-home ratings and system design. The V100 registry’s annual energy entry needs clarification, so it is not used to declare lower running cost.

Compare the key checks

Cabinet height
AprilAire E10015 in.
Santa Fe Ultra V10024 in.
Cabinet width
AprilAire E10014 in.
Santa Fe Ultra V10014.35 in.
Cabinet depth
AprilAire E10026 in.
Santa Fe Ultra V10029 in.

Compare fields recorded for every selected model: differences first, then matching values. Partial data and unknown fields are kept in the expandable table below. Missing data is not a performance disadvantage. Disputed annual energy entries are excluded from the tables; see the certification notes below.

Fields recorded for every selected model. Matching air conditions alone do not guarantee identical methods.
What to checkAprilAire E100 — manufacturer product photographAprilAire E100 →Checked 2026-10-12
Version details

Base E100; current manufacturer page

Santa Fe Ultra V100 current manufacturer product photographSanta Fe Ultra V100 →Checked 2026-10-12
Version details

Current R454B part 4047100; TS-2157 04/26 Rev H

Different recorded values
Certified water removal · whole-home73°F / 60% RH · ducted. ENERGY STAR V6 / DOE Appendix X1. Kept separate from manufacturer ratings, which may use different static pressure or methods.85 pints/day
Notes & sources

ENERGY STAR ID 4510067 · E100 · R32. Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement.

View model sources →
85.62 pints/day
Notes & sources

ENERGY STAR ID 4510404 · 4047100 · R-454B. Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. The annual kWh entry is not reconciled with the public capacity/IEF and annual-method formula; it is retained as reported, but cost arithmetic is withheld until clarified.

View model sources →
Certified integrated energy factor · whole-home73°F / 60% RH · ducted. ENERGY STAR V6 / DOE Appendix X1. Includes low-power modes; do not invert IEF to estimate operating watts.2.35 L/kWh
Notes & sources

ENERGY STAR ID 4510067 · E100 · R32. Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement.

View model sources →
2.45 L/kWh
Notes & sources

ENERGY STAR ID 4510404 · 4047100 · R-454B. Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. The annual kWh entry is not reconciled with the public capacity/IEF and annual-method formula; it is retained as reported, but cost arithmetic is withheld until clarified.

View model sources →
Water removal · 73°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.85 pints/day
Notes & sources

73°F / 60% RH

View model sources →
82 pints/day
Notes & sources

Manufacturer performance at 73°F / 60% RH

View model sources →
Published area · unqualified spaceManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking.Up to 5,500 sq ft
Notes & sources

Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.

View model sources →
Up to 2,300 sq ft · 10 ft ceiling
Notes & sources

Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.

View model sources →
Cabinet heightCabinet dimensions are not installation clearance. Check feet, fittings, airflow and service access.15 in.
Notes & sources

Rounded cabinet dimensions exclude feet, filter doors and duct collars. Check the drawing and installed envelope.

View model sources →
24 in.
Notes & sources

The product page and specification disagree on whether dimensions include duct collars. Check the exact installation drawing before assessing fit.

View model sources →
Cabinet width14 in.
Notes & sources

Rounded cabinet dimensions exclude feet, filter doors and duct collars. Check the drawing and installed envelope.

View model sources →
14.35 in.
Notes & sources

The product page and specification disagree on whether dimensions include duct collars. Check the exact installation drawing before assessing fit.

View model sources →
Cabinet depth26 in.
Notes & sources

Rounded cabinet dimensions exclude feet, filter doors and duct collars. Check the drawing and installed envelope.

View model sources →
29 in.
Notes & sources

Cabinet depth from visually checked manufacturer side-view drawing; excludes external collars.

View model sources →
Minimum operating temperatureA supported operating minimum does not guarantee rated water removal in a cold space.50°F
Notes & sources

Dehumidification inlet-air range is 50°F–104°F, with a minimum 40°F dew point. The ventilation-only range is different and is not used for this filter.

View model sources →
34°F
Notes & sources

Manufacturer exact-part specification; no independent measurement.

View model sources →
Optional external pump · published lift22 ft
Notes & sources

Up to 22 feet lift for separately purchased AprilAire 4856 condensate pump. The base dehumidifier drains by gravity and does not contain this pump.

View model sources →
12 ft
Notes & sources

The exact current model product page links the optional external condensate-pump kit and states up to 12 ft vertical lift. This is a separately purchased accessory, not a built-in pump; confirm the installer package and route.

View model sources →
Manufacturer-listed applicationsListed applications are not a sizing recommendation.Basement, Crawl space, Whole home
Notes & sourcesView model sources →
Commercial, Whole home
Notes & sourcesView model sources →
Same recorded values
Water removal · 80°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.100 pints/day
Notes & sources

80°F / 60% RH

View model sources →
100 pints/day
Notes & sources

Manufacturer performance at 80°F / 60% RH

View model sources →
Drain arrangementGravity drain
Notes & sourcesView model sources →
Gravity drain
Notes & sources

Current manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.

View model sources →
Duct collar diameter10 in.
Notes & sources

10-inch inlet and outlet connections. Duct length and static pressure limits still need the exact installation manual.

View model sources →
10 in.
Notes & sources

10-inch main return and supply connections; optional outdoor-air inlet is 8 in. Duct length/static pressure can require larger connecting ductwork.

View model sources →
Clearance · Either filter extraction side · filter removalRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.15 in.
Notes & sources

PDF p.8 Figure 12 Filter Access Clearance · The filter can be removed from either side; the chosen removal side needs at least 15 inches. Do not count this as cabinet width.

View model sources →
15 in.
Notes & sources

PDF p.5 Location Considerations diagram · The chosen filter-removal side needs 15 in clearance in addition to the cabinet.

View model sources →
Duct connectionSupported; check duct kit
Notes & sources

Duct configuration and required accessories must follow the installation manual.

View model sources →
Supported; check duct kit
Notes & sources

Manufacturer specification; no independent measurement.

View model sources →
Partial data & unknown fields 11 rows

At least one selected model lacks a verified value in each row. The differences may be evidence gaps; they do not establish a better product.

Source-specific values, with missing facts shown explicitly.
What to checkAprilAire E100 — manufacturer product photographAprilAire E100 →Checked 2026-10-12
Version details

Base E100; current manufacturer page

Santa Fe Ultra V100 current manufacturer product photographSanta Fe Ultra V100 →Checked 2026-10-12
Version details

Current R454B part 4047100; TS-2157 04/26 Rev H

Depth including duct collarsIncludes the documented duct collars, but not airflow or service clearance. Missing does not mean no collars.Not verified39.25 in.
Notes & sources

Overall depth with collars attached, confirmed by drawing and specification footer; no service or duct-bend clearance included.

View model sources →
Running current · A80°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.6.7 A
Notes & sources

PDF p.1 Specifications, Current Draw and rating footnote · Manufacturer rated current at 80°F/60% RH inlet air and 0.0 external static pressure. This is current, not input watts or a starting-surge value.

View model sources →
Not verified
Sound level · dBAtemperature not stated · humidity not stated · ducted · distance not stated. Manufacturer claims; missing conditions do not imply identical tests.55 dBA
Notes & sources

PDF p.1 Specifications, Noise row · Manufacturer sound rating for ducted installation. Distance, temperature, humidity and acoustic test method are not given; it is not an independent comparison.

View model sources →
Not verified
Standby power · Wtemperature not stated · humidity not stated · standby. Manufacturer claims; missing conditions do not imply identical tests.< 3 W
Notes & sources

PDF p.4 Operating the Dehumidifier / idle power · Idle only: manufacturer says less than 3 W when both fan and compressor are stopped. This is not operating input power.

View model sources →
Not verified
Input power · W73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.Not verified620 W
Notes & sources

PDF p.1 Electrical, Power · Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

View model sources →
Running current · A104°F · 36% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.Not verified8 A
Notes & sources

PDF p.1 Electrical, Current Draw · Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

View model sources →
Pump hose lengthNot verified
Notes & sources

No included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement.

Not verified
Notes & sources

No included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement.

Clearance · Air return and supply openings · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified12 in.
Notes & sources

PDF p.3 Safety Instructions · Safety text requires at least 12 in at air return and supply; location diagram onp.5 shows 6 in. Ask the manufacturer/installer to reconcile the instructions.

View model sources →
Clearance · Return-air side shown in diagram · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6 in.
Notes & sources

PDF p.5 Location Considerations diagram · Diagram shows 6 in at return side, while safety text onp.3 requires 12 in at return/supply. Do not treat 6 in as an unconditional installation approval.

View model sources →
Clearance · Drain outlet above floor drain · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6.75 in.
Notes & sources

PDF p.12 Drain Installation · For gravity drainage, the drain outlet must be at least 6.75 in above the floor drain, with proper trap and fully supported base.

View model sources →
Clearance · Unit base above secondary drain pan · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6.75 in.
Notes & sources

PDF p.5 Location Considerations · Raise the base 6.75 in above the secondary drain pan to allow the required P-trap. Drain-pan and trap geometry affect total installation height.

View model sources →

Certified efficiency & annual energy

ENERGY STAR V6 ratings use DOE test configurations: whole-home at 73°F / 60% RH, portable at 65°F / 60% RH. The registry’s “portable” category describes the test setup; it does not imply a water bucket. Compare IEF within the same configuration.

2 of 2 selected profiles have a matched active registry entry. Missing entries do not prove that other models were never certified.

AprilAire E100

Whole-home · 73°F / 60% RH · R32

Certified water removal
85 pints/day
Integrated energy factor
2.35 L/kWh
Reported annual energy
821 kWh/year
Annual cost illustration
$164.20

ENERGY STAR partner: Research Products Corporation

Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement.

Registry ID 4510067 · E100 ↗

Santa Fe Ultra V100

Whole-home · 73°F / 60% RH · R-454B

Annual energy needs clarification. The reported number below is excluded from comparison tables and cost calculations because it does not reconcile with the public capacity/IEF and annual method.

Certified water removal
85.62 pints/day
Integrated energy factor
2.45 L/kWh
Reported annual energy
419 kWh/yearNeeds clarification
Annual cost illustration
Withheld · entry needs clarification

ENERGY STAR partner: Research Products Corporation

Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. The annual kWh entry is not reconciled with the public capacity/IEF and annual-method formula; it is retained as reported, but cost arithmetic is withheld until clarified.

Registry ID 4510404 · 4047100 ↗

Cost illustration = reported annual kWh × your tariff. ENERGY STAR’s annual method uses 1,095 dehumidification hours plus low-power energy. It is not a prediction for your moisture load, settings or installation, and IEF is not operating watts. Read the annual method ↗

Compare matching air conditions, then examine the load

Both record 100 pints/day at 80°F/60% RH. E100 lists 85 at 73°F/60% RH and V100 lists 82 there. Those nearby ratings do not establish a statistically meaningful performance advantage; the products were not tested together by us. Actual moisture entry, ventilation air and delivered airflow remain part of sizing. A system that stays above target needs commissioning measurements before a larger-name replacement.

V100 overall depth is not its bare cabinet

E100’s recorded body is 15 inches high, 14 wide and 26 deep, excluding feet and collars. V100 is 24 high and 14.35 wide; its drawing distinguishes 29-inch body depth from 39.25 inches with collars. The product listing’s depth label conflicts with that drawing, so both boundaries are explicit in our table. Allow for duct bends and service space after those dimensions, not within them.

Filter access and drain support remain additional

Both current manuals call for 15 inches for filter extraction. The V100 instructions also specify 6.75 inches of drain elevation and support above a secondary pan. Its safety page asks for 12 inches of airflow clearance while a location diagram shows 6; neither is silently selected as the only requirement. The E100 service and control-side access must also stay available. Sketch these boundaries before selecting a closet or attic position.

Ventilation ports do not design the ventilation system

E100 documents 10-inch main duct connections. V100 documents 10-inch main return and supply connections and an 8-inch outdoor-air inlet. Outdoor-air airflow, damper/control choice and static pressure still need a system design; an extra port alone does not prove compliance or better humidity control. Both base units use gravity drainage, with external pump accessories where required.

The electrical numbers use different regimes

E100 gives 6.7 A at 80°F/60% RH and zero external static pressure. V100 gives 620 W at 73°F/60% RH, but its 8 A current figure is at 104°F/36% RH. Those are different quantities and different loads: multiplying the amps by voltage would not create a comparable operating-watt test. E100’s less-than-3 W standby claim is also separate from dehumidifying power. Use measured operation and duty cycle for a cost assessment.

The current registry adds a separate certified comparison

Both have matched R32/R454B whole-home entries, rated under the Appendix X1 73°F/60% RH ducted configuration. The registry gives E100 85 pints/day and V100 85.62 pints/day as traceable figures in the table; manufacturer values remain separate because their test setup can differ. E100 has IEF 2.35 and V100 2.45. IEF includes low-power modes, so it does not supply operating watts. The V100 reported 419 kWh annual entry does not reconcile with the public rating values and stated annual method; our cost illustration is withheld for that record until clarified.

Reviews & installation evidence

Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.

Video text · installation

E100 installation choices and what an installed quote includes

Earlier version / historical context: E100 in a 2021 installer presentation; hardware revision not identified

The installer explains freestanding and HVAC-connected arrangements, accessible controls and maintenance. Its old installed-price example includes equipment, labor and fees, illustrating why an equipment-only price is incomplete. For a quote today, ask separately about duct routing, controls and drainage. We do not repeat the presentation’s promised energy savings or use its historical price as a current estimate.

Setting / method
Full on-page video text read; Central Ohio installer presentation dated May 2021. Video footage was not inspected.
What this does not prove
Commercial installer explanation, not a measured trial. The transcript mixes water-capacity units and makes unverified savings claims; those are excluded. It is not a test of the current R32 model.
Read the original ↗

Owner report · owner experience

E100 commissioning: similar symptoms can have different causes

Earlier version / historical context: Owner-named E100 units in a 2023–2024 discussion; revisions unreported

The original owner reports persistent duct condensation and humidity settling above the target after a return-to-supply installation. A different participant says manufacturer-assisted measurements led to a warranty replacement and later reports improvement. Together these accounts show why similar symptoms need a measured diagnosis: a model name and long runtime do not establish the cause.

Setting / method
Original post plus a separately identified owner’s replacement follow-up. Different homes and units; neither is a controlled comparative test.
What this does not prove
The replacement outcome belongs to the commenter, not the original poster. No verified measurement logs or exact generation. This does not measure warranty success rates, reliability or current model performance.
Read the original ↗

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualAprilAire E080 & E100 Installation & Owner Manual 02.24

    AprilAire; manufacturer PDF hosted by Sylvane · Checked Oct 12, 2026

    Version: 10020792B, 02.24
  2. manufacturer specAprilAire E100 Specification Form 962 04.24

    AprilAire; manufacturer PDF hosted by Sylvane · Checked Oct 12, 2026

    Version: Form 962, 320925, 04.24
  3. official guidanceDOE Appendix X1: dehumidifier test method

    eCFR / U.S. Department of Energy · Checked Oct 12, 2026

    Version: Current text, title updated through 2026-10-08

    Standard rating conditions differ by configuration. IEF includes low-power modes and is not operating input watts.

  4. official guidanceENERGY STAR registry: Aprilaire E100 (ID 4510067)

    EPA ENERGY STAR · Checked Oct 12, 2026

    Version: V6 registry ID 4510067; R32

    Registry ratings apply to the named configuration and refrigerant; confirm the delivered model label.

Show 7 more sources
  1. official guidanceENERGY STAR registry: Santa Fe 4047100 (ID 4510404)

    EPA ENERGY STAR · Checked Oct 12, 2026

    Version: V6 registry ID 4510404; R-454B

    Registry ratings apply to the named configuration and refrigerant; confirm the delivered model label.

  2. official guidanceENERGY STAR dehumidifier specification: Version 6 final

    EPA ENERGY STAR · Checked Oct 12, 2026

    Version: Final V6, effective October 1, 2025

    Annual consumption is a standardized test-based estimate using1095 annual dehumidification hours and low-power energy. It does not predict a particular household bill.

  3. official guidanceENERGY STAR certified dehumidifiers: active Version 6 dataset

    EPA ENERGY STAR · Checked Oct 12, 2026

    Version: Active V6 dataset, retrieved 2026-10-12

    Certification entries use exact names and configurations. Absence from this snapshot does not prove that a product has never been certified.

  4. installer reviewAprilaire E100 Whole Home Dehumidifier Review

    Fire & Ice · Checked Oct 12, 2026

    Version: E100 in a 2021 installer presentation; hardware revision not identified

    External evidence; the summary identifies its scope and limits. Follow the original for the full account.

  5. owner reviewAprilaire e100 struggling to lower humidity

    Reddit r/hvacadvice · Checked Oct 12, 2026

    Version: Owner-named E100 units in a 2023–2024 discussion; revisions unreported

    External evidence; the summary identifies its scope and limits. Follow the original for the full account.

  6. manufacturer specSanta Fe Ultra V100 4047100 manufacturer specification TS-2152

    Santa Fe · Checked Oct 12, 2026

  7. manufacturer manualSanta Fe TS-2157 04/26 Rev H installation and operation manual

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2157 04/26 Rev H