Documented model profile

Santa Fe Ultra V100

A current R454B ducted/ventilating whole-home dehumidifier, part 4047100, with 100 pints/day at 80°F/60% RH. It uses gravity drainage and needs room for ducting, service access and a P-trap; any condensate lift uses a separate pump.

Model Ultra V100 / 4047100 · Current R454B part 4047100; TS-2157 04/26 Rev H
Checked Oct 11, 2026 · current

Santa Fe Ultra V100 current manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
100 pints/day80°F / 60% RH
82 pints/day73°F / 60% RH
Drain arrangement
gravityCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
Cabinet height
24 in.Product page labels the same dimensions without collars; current spec footer says with collars. Check the installation drawing and exact outlet arrangement rather than treating this as a guaranteed fit.
Cabinet width
14.35 in.Product page labels the same dimensions without collars; current spec footer says with collars. Check the installation drawing and exact outlet arrangement rather than treating this as a guaranteed fit.
Cabinet depth
39.25 in.Product page labels the same dimensions without collars; current spec footer says with collars. Check the installation drawing and exact outlet arrangement rather than treating this as a guaranteed fit.
Minimum inlet-air temperature
34°FManufacturer exact-part specification; no independent measurement.
Power at published conditions
620 WManufacturer rated watts at 73°F/60% RH; actual use varies.
Noise measurement
Not verifiedNot confirmed in the checked sources.
Duct connection
YesManufacturer specification; no independent measurement.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Where it may fit

  • A designed whole-home ducted/ventilating installation with sufficient service and drain clearance.

Before you buy

  • Check that the seller supplies the exact current part number and R454B generation shown here.
  • Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.
  • Current manual requires at least 6.75 in drain-outlet elevation for the P-trap. The cabinet height alone is not the installed height.

The tradeoffs

  • Capacity depends on inlet conditions; a rated floor area is not a guaranteed match for an unsealed or actively leaking space.
  • Product/spec wording disagrees about whether dimensions include collars; confirm the specific outlet configuration before ordering.

Reviews & installation evidence

Independent evidence is still being collected.

Current manufacturer product page, exact-part R454B specification and available current installation manual checked 2026-10-11. We have not independently tested this device.

We will add concise summaries of relevant tests, installations and owner experience, with links and limitations.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer productSanta Fe Ultra V100 manufacturer product page

    Santa-Fe · Checked Oct 11, 2026

    Open verified alternative ↗

    Manufacturer page readable via web retrieval; automated local HTTP requests return 403. Exact current manufacturer specification PDF is the fallback.

    Ideal Applications; Product Specifications: Part Number, Pint Capacity, Power with stated temperature/RH, Operating Temperature, Performance At, Unit Dimensions; ducting and control features.

    Current part number is used as generation identity. Older R410A/R134A data and legacy category descriptions are not merged. Current product page is not an independent test; complete drain installation remains to be checked from its matching manual. Rechecked exact current part 2026-10-11; conflicting figures are retained in field notes and buying checks.

  2. manufacturer specSanta Fe Ultra V100 4047100 manufacturer specification TS-2152

    Santa Fe · Checked Oct 11, 2026

    Version: Current R454B exact-part specification asset checked 2026-10-11First page: exact model/part number, capacity with conditions, dimensions, power, temperature and drain. First-page embedded manufacturer photograph is extracted for editorial identification.

    Current manufacturer media-resource library points to this exact-part PDF. Dimensions exclude service access. Source notes about collared/uncollared dimensions and other conflicts appear in the model record.

  3. manufacturer manualSanta Fe TS-2157 04/26 Rev H installation and operation manual

    Santa Fe · Checked Oct 11, 2026

    Version: TS-2157 04/26 Rev HDrain Installation page 12; registrations page 4 gives all three exact part numbers; location page 5 requires 6.75 in elevation for a P-trap.

    Exact current part-number document. External pump is optional, not built in. Advance Dry 110 TS2135 includes apparent Advance Dry 100 naming typos in drainage text; cover/registrations identify 4047010.