An editorial comparison

AlorAir HDi65S vs Santa Fe Ultra70: built-in pump or ducted gravity drain?

A pump-equipped Sentinel and a low-profile Ultra model. Compare the exact 55/70-pint warm ratings, drain route and installation documentation.

Checked Oct 12, 2026 · Exact base models identified below

The useful difference

Examine HDi65S when a built-in pump is central to the location, after confirming the exact pump limit. Examine Ultra70 when its gravity drain and documented duct layout work for the space. The larger number in the HDi65S name is not a verified 65-pint warm-condition rating.

Compare the key checks

Built-in pump · published lift
AlorAir Sentinel HDi65S19.6 ft
Santa Fe Ultra70Not verified
Cabinet height
AlorAir Sentinel HDi65S13.3 in.
Santa Fe Ultra7012 in.
Cabinet width
AlorAir Sentinel HDi65S12.2 in.
Santa Fe Ultra7012 in.

Compare fields recorded for every selected model: differences first, then matching values. Partial data and unknown fields are kept in the expandable table below. Missing data is not a performance disadvantage.

Fields recorded for every selected model. Matching air conditions alone do not guarantee identical methods.
What to checkAlorAir Sentinel HDi65S — manufacturer product photographAlorAir Sentinel HDi65S →Checked 2026-10-12
Version details

Ordinary non-Wi-Fi Black HDi65S; SKU RF02ALOS-Sentinel-HDi65S-0YDMB00; R32 specification dated 20251219 in filename

Santa Fe Ultra70 — manufacturer product photographSanta Fe Ultra70 →Checked 2026-10-12
Version details

Part 4044100; current product page

Different recorded values
Water removal · 80°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.55 pints/day
Notes & sources

Manufacturer AHAM rating · AHAM

View model sources →
70 pints/day
Notes & sources

80°F / 60% RH

View model sources →
Drain arrangementBuilt-in pump
Notes & sources

Pump and/or gravity mode as stated in the named product specification; mode and hose setup must be checked in the exact manual.

View model sources →
Gravity drain
Notes & sources

Manufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions.

View model sources →
Published area · unqualified spaceManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking.Up to 1,300 sq ft
Notes & sources

Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.

View model sources →
Up to 1,800 sq ft · 10 ft ceiling
Notes & sources

Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.

View model sources →
Cabinet heightCabinet dimensions are not installation clearance. Check feet, fittings, airflow and service access.13.3 in.
Notes & sources

Cabinet dimensions are from the R32 drawing. Leave extra space for airflow, fittings and service access.

View model sources →
12 in.
Notes & sourcesView model sources →
Cabinet width12.2 in.
Notes & sources

Cabinet dimensions are from the R32 drawing. Leave extra space for airflow, fittings and service access.

View model sources →
12 in.
Notes & sourcesView model sources →
Cabinet depth19.2 in.
Notes & sources

Cabinet dimensions are from the R32 drawing. Leave extra space for airflow, fittings and service access.

View model sources →
22 in.
Notes & sources

22-inch cabinet body without duct collars. With the documented collars, depth is 28 inches; leave additional airflow and service clearance.

View model sources →
Minimum operating temperatureA supported operating minimum does not guarantee rated water removal in a cold space.33.8°F
Notes & sources

Manufacturer product specification; not independently measured.

View model sources →
49°F
Notes & sourcesView model sources →
Manufacturer-listed applicationsListed applications are not a sizing recommendation.Basement, Crawl space
Notes & sourcesView model sources →
Basement, Crawl space, Whole home
Notes & sourcesView model sources →
Same recorded values
Duct connectionSupported; check duct kit
Notes & sources

The linked exact-model manufacturer specification explicitly describes optional duct mounting and a ducted installation. Confirm the matching collar kit and installed airflow requirements.

View model sources →
Supported; check duct kit
Notes & sources

Duct configuration and required accessories must follow the installation manual.

View model sources →
Partial data & unknown fields 18 rows

At least one selected model lacks a verified value in each row. The differences may be evidence gaps; they do not establish a better product.

Source-specific values, with missing facts shown explicitly.
What to checkAlorAir Sentinel HDi65S — manufacturer product photographAlorAir Sentinel HDi65S →Checked 2026-10-12
Version details

Ordinary non-Wi-Fi Black HDi65S; SKU RF02ALOS-Sentinel-HDi65S-0YDMB00; R32 specification dated 20251219 in filename

Santa Fe Ultra70 — manufacturer product photographSanta Fe Ultra70 →Checked 2026-10-12
Version details

Part 4044100; current product page

Certified water removal · portable65°F / 60% RH · unducted. ENERGY STAR V6 / DOE Appendix X1. Kept separate from manufacturer ratings, which may use different static pressure or methods.36.33 pints/day
Notes & sources

ENERGY STAR ID 4005597 · Sentinel HDI65S · HFC-32. Family rating shared with HD55S. Explicit additional model in this certification family. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. This is a family entry with an explicitly named additional model; the rating alone does not distinguish pump equipment. Both the ALORAIR and ABESTORM entries name AlorAir Solutions Inc. as their ENERGY STAR partner. This does not establish identical hardware or interchangeable parts.

View model sources →
Not verified
Certified integrated energy factor · portable65°F / 60% RH · unducted. ENERGY STAR V6 / DOE Appendix X1. Includes low-power modes; do not invert IEF to estimate operating watts.2.08 L/kWh
Notes & sources

ENERGY STAR ID 4005597 · Sentinel HDI65S · HFC-32. Family rating shared with HD55S. Explicit additional model in this certification family. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. This is a family entry with an explicitly named additional model; the rating alone does not distinguish pump equipment. Both the ALORAIR and ABESTORM entries name AlorAir Solutions Inc. as their ENERGY STAR partner. This does not establish identical hardware or interchangeable parts.

View model sources →
Not verified
Registry annual energy estimate · portable65°F / 60% RH · unducted. ENERGY STAR V6 / DOE Appendix X1. Standardized reported energy, not an operating-watt reading or household bill prediction.379 kWh/year
Notes & sources

ENERGY STAR ID 4005597 · Sentinel HDI65S · HFC-32. Family rating shared with HD55S. Explicit additional model in this certification family. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. This is a family entry with an explicitly named additional model; the rating alone does not distinguish pump equipment. Both the ALORAIR and ABESTORM entries name AlorAir Solutions Inc. as their ENERGY STAR partner. This does not establish identical hardware or interchangeable parts.

View model sources →
Not verified
Water removal · 73°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.Not verified52.45 pints/day
Notes & sources

73°F / 60% RH

View model sources →
Water removal · 90°F / 90% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.120 pints/day
Notes & sources

Manufacturer saturation rating

View model sources →
Not verified
Depth including duct collarsIncludes the documented duct collars, but not airflow or service clearance. Missing does not mean no collars.Not verified28 in.
Notes & sources

Includes the documented duct collars, but not airflow or service clearance.

View model sources →
Sound level · dBAtemperature not stated · humidity not stated · configuration not stated · distance not stated. Manufacturer claims; missing conditions do not imply identical tests.< 52 dBA
Notes & sources

Product-page specification table: Noise Level · Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.

PDF p1, sound-pressure specification row · Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.

View model sources →
Not verified
Running current · Atemperature not stated · humidity not stated · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.4.1 A
Notes & sources

PDF p1, current/power specification row · Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.

View model sources →
Not verified
Input power · W73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.Not verified492 W
Notes & sources

PDF p.1 Electrical, Power · Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

View model sources →
Running current · A73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.Not verified4.1 A
Notes & sources

PDF p.1 Electrical, Current Draw · Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

View model sources →
Built-in pump · published liftPublished head limit, not a guarantee for a long hose with bends. Conflicting claims are not a safe installation limit.19.6 ft
Notes & sources

Explicit manufacturer vertical-lift/drain-height claim for this listing. Confirm the exact model, tubing route and hydraulic limits in the delivered-unit manual; no independent pump test is claimed.

PDF p13 and p15, pump-discharge diagrams · The linked manual labels a vertical rise 19.6 ft, but does not establish the exact current R32 production revision.

View model sources →
Not verified
Optional external pump · published liftNot verified12 ft
Notes & sources

Optional external 4022220 pump is rated up to 12 ft vertical lift; Ultra 70 base unit drains by gravity.

View model sources →
Pump hose length19.6 ft
Notes & sources

Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.

View model sources →
Not verified
Notes & sources

No included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement.

Duct collar diameterNot verified
Notes & sources

No single current-generation duct connection diameter confirmed; inlet and supply ports may differ.

8 in.
Notes & sources

8 in main inlet/outlet collars. Longer duct runs can require a larger duct than the connector.

View model sources →
Clearance · Return and supply openings · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified12 in.
Notes & sources

PDF p.3 Safety Instructions · Safety text requires 12 in, whereas the location diagram shows 6 in.

View model sources →
Clearance · Return side in location diagram · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6 in.
Notes & sources

PDF p.5 Location diagram · Diagram shows 6 in airflow clearance; conflicts with 12 in safety text.

View model sources →
Clearance · Either filter extraction side · filter removalRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified13 in.
Notes & sources

PDF p.5 Location diagram · Keep 13 in free at the filter-removal side.

View model sources →
Clearance · Drain outlet above floor drain · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6.75 in.
Notes & sources

PDF p.7 Drain Installation · Mount so the drain outlet is at least 6.75 in above the floor drain; required trap and supports increase installation height.

View model sources →

Certified efficiency & annual energy

ENERGY STAR V6 ratings use DOE test configurations: whole-home at 73°F / 60% RH, portable at 65°F / 60% RH. The registry’s “portable” category describes the test setup; it does not imply a water bucket. Compare IEF within the same configuration.

1 of 2 selected profiles have a matched active registry entry. Missing entries do not prove that other models were never certified.

AlorAir Sentinel HDi65S

Portable test · 65°F / 60% RH · HFC-32

Family rating shared with HD55S →
The shared test entry does not distinguish pump equipment or establish identical hardware.

Certified water removal
36.33 pints/day
Integrated energy factor
2.08 L/kWh
Reported annual energy
379 kWh/year
Annual cost illustration
$75.80

ENERGY STAR partner: AlorAir Solutions Inc.

Explicit additional model in this certification family. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. This is a family entry with an explicitly named additional model; the rating alone does not distinguish pump equipment. Both the ALORAIR and ABESTORM entries name AlorAir Solutions Inc. as their ENERGY STAR partner. This does not establish identical hardware or interchangeable parts.

Registry ID 4005597 · Sentinel HDI65S ↗

Cost illustration = reported annual kWh × your tariff. ENERGY STAR’s annual method uses 1,095 dehumidification hours plus low-power energy. It is not a prediction for your moisture load, settings or installation, and IEF is not operating watts. Read the annual method ↗

Read the capacity table instead of the model name

The checked HDi65S specification gives 55 pints/day at 80°F/60% RH, while Ultra70 gives 70 at those conditions. HDi65S’s 120-pint claim belongs to a hotter, wetter regime shown separately. Neither that maximum nor the 65 in the product name should replace the condition-labelled rating. The table exposes this distinction before any fit or drain decision.

Different drain arrangements change the installation

HDi65S includes a pump. Ultra70 drains by gravity and can use a separate compatible pump. A linked HDi65S manual shows a 19.6-foot rise, but does not establish the exact current R32 production revision; the single normalized lift remains unknown. The external Santa Fe pump limit is an accessory specification, not an Ultra70 built-in capability. Confirm both the route and overflow response.

Cabinet, collars and drain elevation must all fit

HDi65S records a 13.3-inch-high body, 12.2-inch width and 19.2-inch depth. Ultra70 records 12 by 12 by 22, extending to 28 inches with collars. That makes Ultra70’s body lower but does not settle the installed height: its current instructions specify drain elevation and 13 inches of filter-extraction space. Include those requirements in the location sketch.

Duct support needs the exact accessories and airflow plan

Both profiles have source-supported duct capability, but that does not make every inlet/outlet or accessory interchangeable. The older Sentinel manual discusses a supply grille without establishing current collar compatibility. Ultra70’s current installation manual is the starting point for its return, supply and drain arrangement; it also contains differing numerical airflow instructions that need clarification in a tight location. Avoid choosing ducts from the brand or family name alone.

Current, watts and sound cannot declare a winner

The visible HDi65S specification gives 4.1 A; its sound claim is less than 52 dBA with no measuring distance. Ultra70 provides direct operating watts at stated conditions, but no matching sound test was verified. Amps are not converted to watts, and a sound upper bound is not an exact measurement. The available documents cannot establish comparative yearly cost or room-above quietness.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualAlorAir Sentinel HDi65S linked installation and operation manual

    AlorAir · Checked Oct 12, 2026

    Version: Manufacturer-linked manual

    Exact model manual currently linked by the manufacturer; match the delivered model plate and document revision before installation.

  2. manufacturer productAlorAir Sentinel HDi65S manufacturer product page

    AlorAir · Checked Oct 12, 2026

  3. manufacturer specAlorAir Sentinel HDi65S current linked specification sheet

    AlorAir · Checked Oct 12, 2026

    Version: File identifier 20251219
  4. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.

    Alternative source

Show 3 more sources
  1. manufacturer specSanta Fe Ultra70 4044100 Specification Sheet TS-2111 Rev B

    Santa Fe / AprilAire official DAM · Checked Oct 12, 2026

    Version: TS-2111 Rev B, 01/26

    The drawing separates a 22-inch body from a 28-inch depth with duct collars; service clearance is additional.

  2. manufacturer manualSanta Fe Ultra70 4044100 Installation Instructions

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2082 Rev C / 04.26

    Exact 4044100 instruction manual. Safety text asks for 12 inches at return/supply, while the location diagram shows 6 inches. Filter removal requires 13 inches. Do not silently choose the smaller airflow clearance.

  3. manufacturer specSanta Fe Ultra70 4044100 Specification

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2111 Rev B / 01.26

    Exact 4044100 R454B specification. Input power and current are both rated at 73°F/60% RH. No numeric sound level is published here.