Documented model profile

Santa Fe Ultra70

The Ultra70 adds a ducted whole-home use case to a low cabinet. It is deeper than the Compact70, so a height-only shortlist can miss an important installation constraint.

Model 4044100 · Part 4044100; current product page
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
12 × 12 × 22 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Santa Fe Ultra70 — manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
70 pints/day80°F / 60% RH
52.45 pints/day73°F / 60% RH
Drain arrangement
Gravity drainManufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions.
Cabinet height
12 in.
Cabinet width
12 in.
Cabinet depth
22 in.22-inch cabinet body without duct collars. With the documented collars, depth is 28 inches; leave additional airflow and service clearance.
Depth including duct collars
28 in.Includes the documented duct collars, but not airflow or service clearance.
Minimum inlet-air temperature
49°F
Noise measurement
Not verifiedComparable independent noise measurements have not been verified.
Duct connection
YesDuct configuration and required accessories must follow the installation manual.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • Manufacturer area statementUp to 1,800 sq ft

    Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

  • Input power492 W

    73°F · 60% RH · configuration not stated

    Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

    PDF p.1 Electrical, Power · Santa Fe ↗
  • Running current4.1 A

    73°F · 60% RH · configuration not stated

    Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

    PDF p.1 Electrical, Current Draw · Santa Fe ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
12 ft

Optional external 4022220 pump is rated up to 12 ft vertical lift; Ultra 70 base unit drains by gravity.

Published specification · Santa Fe ↗
Duct collar diameter
8 in.

8 in main inlet/outlet collars. Longer duct runs can require a larger duct than the connector.

Published specification · Santa Fe ↗ / Santa Fe ↗
  • Return and supply openings · airflow12 in.

    Safety text requires 12 in, whereas the location diagram shows 6 in.

    PDF p.3 Safety Instructions · Santa Fe ↗
  • Return side in location diagram · airflow6 in.

    Diagram shows 6 in airflow clearance; conflicts with 12 in safety text.

    PDF p.5 Location diagram · Santa Fe ↗
  • Either filter extraction side · filter removal13 in.

    Keep 13 in free at the filter-removal side.

    PDF p.5 Location diagram · Santa Fe ↗
  • Drain outlet above floor drain · drain6.75 in.

    Mount so the drain outlet is at least 6.75 in above the floor drain; required trap and supports increase installation height.

    PDF p.7 Drain Installation · Santa Fe ↗

12 in safety text and 6 in airflow diagram are retained separately.

Source discrepancy · Santa Fe ↗

Where it may fit

  • A crawl space installation with a verified drainage and airflow plan.
  • A basement installation with a verified drainage and airflow plan.
  • A whole home installation with a verified drainage and airflow plan.

Before you buy

  • Use inlet-air limits when assessing low-temperature operation.
  • Measure depth and service access as well as height.

The tradeoffs

  • The 34°F cabinet-ambient allowance is not the inlet-air minimum.
  • Duct design needs a separate installation check.

Reviews & installation evidence

Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.

Manufacturer manual · installation

Santa Fe Ultra70 Installation & Operation Instructions

Identified model: 4044100; TS-2082 04/26 Rev C

The manual makes duct arrangement a buying decision rather than an afterthought. Its preferred layout uses a dedicated central return and feeds dry air into the HVAC supply through a backdraft damper. Alternative layouts can require blower coordination; return-to-return is described as a last-resort choice because it can reduce the air conditioner's moisture removal. Separate duct distribution is addressed for homes using mini-splits. The drainage section calls for a trap, with an optional pump when water must be lifted. Buyers should budget for the required control, damper, drain protection and airflow work, then have an installer check the proposed layout against the full manual.

Setting / method
Part 4044100; installation requirements for the documented Ultra70 generation.
What this does not prove
Manufacturer guidance, not field measurements. This digest is a planning aid; full instructions and site-specific commissioning remain necessary.
Read the original ↗

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.

    Alternative source

  2. manufacturer manualSanta Fe Ultra70 4044100 Installation Instructions TS-2082 Rev C

    Santa Fe / AprilAire official DAM · Checked Oct 12, 2026

    Version: TS-2082 Rev C, 04/26
  3. manufacturer specSanta Fe Ultra70 4044100 Specification Sheet TS-2111 Rev B

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2111 Rev B, 01/26
  4. manufacturer manualSanta Fe Ultra70 4044100 Installation Instructions

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2082 Rev C / 04.26

    Exact 4044100 instruction manual. Safety text asks for 12 inches at return/supply, while the location diagram shows 6 inches. Filter removal requires 13 inches. Do not silently choose the smaller airflow clearance.

Show 1 more source
  1. manufacturer specSanta Fe Ultra70 4044100 Specification

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2111 Rev B / 01.26

    Exact 4044100 R454B specification. Input power and current are both rated at 73°F/60% RH. No numeric sound level is published here.