An editorial comparison
Santa Fe Compact70 vs Ultra70: depth and ducting
Two 12-inch-high cabinets with different installation footprints and applications.
Checked Oct 11, 2026 · Exact base models identified below
The useful difference
Both publish 70 pints at 80°F / 60% RH. Compact70 is the shallower cabinet; Ultra70 explicitly includes a whole-home application. Check the duct kit, drain arrangement and service clearance before choosing.
Compare the key checks
Compare fields recorded for every selected model: differences first, then matching values. Partial data and unknown fields are kept in the expandable table below. Missing data is not a performance disadvantage.
| What to check | Santa Fe Compact70 →Checked 2026-10-12Version detailsPart 4044110; current product page | Santa Fe Ultra70 →Checked 2026-10-12Version detailsPart 4044100; current product page |
|---|---|---|
| Different recorded values | ||
| Cabinet depth | 21 in.Notes & sourcesView model sources → | 22 in.Notes & sources22-inch cabinet body without duct collars. With the documented collars, depth is 28 inches; leave additional airflow and service clearance. View model sources → |
| Manufacturer-listed applicationsListed applications are not a sizing recommendation. | Basement, Crawl spaceNotes & sourcesView model sources → | Basement, Crawl space, Whole homeNotes & sourcesView model sources → |
| Same recorded values | ||
| Water removal · 80°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test. | 70 pints/day | 70 pints/day |
| Drain arrangement | Gravity drainNotes & sourcesManufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions. View model sources → | Gravity drainNotes & sourcesManufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions. View model sources → |
| Cabinet heightCabinet dimensions are not installation clearance. Check feet, fittings, airflow and service access. | 12 in.Notes & sourcesView model sources → | 12 in.Notes & sourcesView model sources → |
| Cabinet width | 12 in.Notes & sourcesView model sources → | 12 in.Notes & sourcesView model sources → |
| Minimum operating temperatureA supported operating minimum does not guarantee rated water removal in a cold space. | 49°FNotes & sourcesView model sources → | 49°FNotes & sourcesView model sources → |
| Optional external pump · published lift | 12 ftNotes & sourcesUp to 12 ft vertical lift for compatible optional external 4022220 pump; the base Compact 70 has gravity drainage. View model sources → | 12 ftNotes & sourcesOptional external 4022220 pump is rated up to 12 ft vertical lift; Ultra 70 base unit drains by gravity. View model sources → |
| Duct collar diameter | 8 in.Notes & sourcesOptional duct kit uses 8 in return and supply connections. Confirm the ordered kit and included collar configuration. View model sources → | 8 in.Notes & sources8 in main inlet/outlet collars. Longer duct runs can require a larger duct than the connector. View model sources → |
| Clearance · Return and supply openings · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | 12 in.Notes & sourcesPDF p.3 Safety Instructions · General safety text says 12 in; detailed diagram shows 11 in return and 24 in supply, requiring installer interpretation. View model sources → | 12 in.Notes & sourcesPDF p.3 Safety Instructions · Safety text requires 12 in, whereas the location diagram shows 6 in. View model sources → |
| Duct connection | Supported; check duct kitNotes & sourcesDuct configuration and required accessories must follow the installation manual. View model sources → | Supported; check duct kitNotes & sourcesDuct configuration and required accessories must follow the installation manual. View model sources → |
Partial data & unknown fields 18 rows
At least one selected model lacks a verified value in each row. The differences may be evidence gaps; they do not establish a better product.
| What to check | Santa Fe Compact70 →Checked 2026-10-12Version detailsPart 4044110; current product page | Santa Fe Ultra70 →Checked 2026-10-12Version detailsPart 4044100; current product page |
|---|---|---|
| Water removal · 73°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test. | Not verified | 52.45 pints/day |
| Water removal · 65°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test. | 43.7 pints/day | Not verified |
| Published area · unqualified spaceManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking. | Not verified | Up to 1,800 sq ft · 10 ft ceilingNotes & sourcesManufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment. View model sources → |
| Published area · Crawl spaceManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking. | 1,800–2,600 sq ft · 5 ft ceilingNotes & sourcesManufacturer sizing claim assumes a 5-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 1,800–2,600 sq ft sizing range without identifying which conditions support its upper end. View model sources → | Not verified |
| Published area · BasementManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking. | 1,800–2,200 sq ft · 10 ft ceilingNotes & sourcesManufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 1,800–2,200 sq ft sizing range without identifying which conditions support its upper end. View model sources → | Not verified |
| Depth including duct collarsIncludes the documented duct collars, but not airflow or service clearance. Missing does not mean no collars. | Not verified | 28 in.Notes & sourcesIncludes the documented duct collars, but not airflow or service clearance. View model sources → |
| Input power · W65°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests. | 444 WNotes & sourcesPDF p.1 Electrical, Power · Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified. View model sources → | Not verified |
| Running current · A65°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests. | 3.7 ANotes & sourcesPDF p.1 Electrical, Current Draw · Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts. View model sources → | Not verified |
| Input power · W73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests. | Not verified | 492 WNotes & sourcesPDF p.1 Electrical, Power · Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified. View model sources → |
| Running current · A73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests. | Not verified | 4.1 ANotes & sourcesPDF p.1 Electrical, Current Draw · Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts. View model sources → |
| Pump hose length | Not verifiedNotes & sourcesNo included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement. | Not verifiedNotes & sourcesNo included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement. |
| Clearance · Return/filter side · filter removalRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | 11 in.Notes & sourcesPDF p.5 Location diagram · Diagram shows 11 in for filter removal and return airflow; safety text separately asks for 12 in at return/supply. View model sources → | Not verified |
| Clearance · Return side · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | 11 in.Notes & sourcesPDF p.5 Location diagram · The 11 in return-side figure differs from the 12 in general safety instruction; do not silently use the smaller value. View model sources → | Not verified |
| Clearance · Supply side · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | 24 in.Notes & sourcesPDF p.5 Location diagram · Diagram calls for 24 in at the supply outlet, beyond cabinet depth. View model sources → | Not verified |
| Clearance · Highest point of drain trap below drain-port adapter · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | 2 in.Notes & sourcesPDF p.6 Drain Installation · The highest point of the hose trap must remain at least 2 in below the black drain adapter; trap is positioned 8–10 in from the unit. View model sources → | Not verified |
| Clearance · Return side in location diagram · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | Not verified | 6 in.Notes & sourcesPDF p.5 Location diagram · Diagram shows 6 in airflow clearance; conflicts with 12 in safety text. View model sources → |
| Clearance · Either filter extraction side · filter removalRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | Not verified | 13 in.Notes & sourcesPDF p.5 Location diagram · Keep 13 in free at the filter-removal side. View model sources → |
| Clearance · Drain outlet above floor drain · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit. | Not verified | 6.75 in.Notes & sourcesPDF p.7 Drain Installation · Mount so the drain outlet is at least 6.75 in above the floor drain; required trap and supports increase installation height. View model sources → |
The shared number
Both list 70 pints per day at the same warm rating point. Cooler-condition figures use different temperatures, so they are shown separately rather than turned into a score.
The space you actually need
Compact70 is listed at 21 inches deep. Ultra70 is 28 inches with duct collars and 22 inches without them. Both list 12-inch cabinet height and width. Add airflow, service and drain space from the exact manual; the cabinet dimensions alone do not decide the installed footprint.
Reviews & installation evidence
Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.
Article · installation
Compact70 placement: rotatable outlet, hanging kit and controls
Earlier version / historical context: Compact70 described in March 2023; current part 4044110 equivalence not established
Sylvane describes rotating the discharge panel for vertical exhaust and using a separately purchased hanging kit between joists. The article also covers optional ducting and the onboard humidity dial. This is useful when planning access and accessories, but the installation still needs space for ducts, filter removal and a downhill drain. The retailer’s stated coverage is not a sizing guarantee.
- Setting / method
- Retailer editorial review with placement discussion and published specification tables; no repeatable test protocol or raw results supplied.
- What this does not prove
- The retailer sells this brand. The 2023 unit is not identified by current part number or refrigerant; measurements, warranty wording and accessory fit must be checked against current documents.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer specSanta Fe Compact70 4044110 Data Sheet TS-2108 Rev B
Santa Fe · Checked Oct 12, 2026
Version: TS-2108 Rev B, 01/26 - manufacturer specSanta Fe Ultra70 4044100 Specification Sheet TS-2111 Rev B
Santa Fe · Checked Oct 12, 2026
Version: TS-2111 Rev B, 01/26 - retailerSylvane Reviews: The Santa Fe Compact70 Dehumidifier
Sylvane · Checked Oct 12, 2026
Version: Compact70 described in March 2023; current part 4044110 equivalence not establishedExternal evidence; the summary identifies its scope and limits. Follow the original for the full account.