An editorial comparison

Santa Fe Compact70 vs Ultra70: depth and ducting

Two 12-inch-high cabinets with different installation footprints and applications.

Checked Oct 11, 2026 · Exact base models identified below

The useful difference

Both publish 70 pints at 80°F / 60% RH. Compact70 is the shallower cabinet; Ultra70 explicitly includes a whole-home application. Check the duct kit, drain arrangement and service clearance before choosing.

Compare the key checks

Cabinet depth
Santa Fe Compact7021 in.
Santa Fe Ultra7022 in.
Cabinet height
Santa Fe Compact7012 in.
Santa Fe Ultra7012 in.
Cabinet width
Santa Fe Compact7012 in.
Santa Fe Ultra7012 in.

Compare fields recorded for every selected model: differences first, then matching values. Partial data and unknown fields are kept in the expandable table below. Missing data is not a performance disadvantage.

Fields recorded for every selected model. Matching air conditions alone do not guarantee identical methods.
What to checkSanta Fe Compact70 — manufacturer product photographSanta Fe Compact70 →Checked 2026-10-12
Version details

Part 4044110; current product page

Santa Fe Ultra70 — manufacturer product photographSanta Fe Ultra70 →Checked 2026-10-12
Version details

Part 4044100; current product page

Different recorded values
Cabinet depth21 in.
Notes & sourcesView model sources →
22 in.
Notes & sources

22-inch cabinet body without duct collars. With the documented collars, depth is 28 inches; leave additional airflow and service clearance.

View model sources →
Manufacturer-listed applicationsListed applications are not a sizing recommendation.Basement, Crawl space
Notes & sourcesView model sources →
Basement, Crawl space, Whole home
Notes & sourcesView model sources →
Same recorded values
Water removal · 80°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.70 pints/day
Notes & sources

80°F / 60% RH

View model sources →
70 pints/day
Notes & sources

80°F / 60% RH

View model sources →
Drain arrangementGravity drain
Notes & sources

Manufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions.

View model sources →
Gravity drain
Notes & sources

Manufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions.

View model sources →
Cabinet heightCabinet dimensions are not installation clearance. Check feet, fittings, airflow and service access.12 in.
Notes & sourcesView model sources →
12 in.
Notes & sourcesView model sources →
Cabinet width12 in.
Notes & sourcesView model sources →
12 in.
Notes & sourcesView model sources →
Minimum operating temperatureA supported operating minimum does not guarantee rated water removal in a cold space.49°F
Notes & sourcesView model sources →
49°F
Notes & sourcesView model sources →
Optional external pump · published lift12 ft
Notes & sources

Up to 12 ft vertical lift for compatible optional external 4022220 pump; the base Compact 70 has gravity drainage.

View model sources →
12 ft
Notes & sources

Optional external 4022220 pump is rated up to 12 ft vertical lift; Ultra 70 base unit drains by gravity.

View model sources →
Duct collar diameter8 in.
Notes & sources

Optional duct kit uses 8 in return and supply connections. Confirm the ordered kit and included collar configuration.

View model sources →
8 in.
Notes & sources

8 in main inlet/outlet collars. Longer duct runs can require a larger duct than the connector.

View model sources →
Clearance · Return and supply openings · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.12 in.
Notes & sources

PDF p.3 Safety Instructions · General safety text says 12 in; detailed diagram shows 11 in return and 24 in supply, requiring installer interpretation.

View model sources →
12 in.
Notes & sources

PDF p.3 Safety Instructions · Safety text requires 12 in, whereas the location diagram shows 6 in.

View model sources →
Duct connectionSupported; check duct kit
Notes & sources

Duct configuration and required accessories must follow the installation manual.

View model sources →
Supported; check duct kit
Notes & sources

Duct configuration and required accessories must follow the installation manual.

View model sources →
Partial data & unknown fields 18 rows

At least one selected model lacks a verified value in each row. The differences may be evidence gaps; they do not establish a better product.

Source-specific values, with missing facts shown explicitly.
What to checkSanta Fe Compact70 — manufacturer product photographSanta Fe Compact70 →Checked 2026-10-12
Version details

Part 4044110; current product page

Santa Fe Ultra70 — manufacturer product photographSanta Fe Ultra70 →Checked 2026-10-12
Version details

Part 4044100; current product page

Water removal · 73°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.Not verified52.45 pints/day
Notes & sources

73°F / 60% RH

View model sources →
Water removal · 65°F / 60% RHManufacturer ratings at these stated conditions. Test methods may still differ; this is not an independent performance test.43.7 pints/day
Notes & sources

65°F / 60% RH

View model sources →
Not verified
Published area · unqualified spaceManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking.Not verifiedUp to 1,800 sq ft · 10 ft ceiling
Notes & sources

Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.

View model sources →
Published area · Crawl spaceManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking.1,800–2,600 sq ft · 5 ft ceiling
Notes & sources

Manufacturer sizing claim assumes a 5-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 1,800–2,600 sq ft sizing range without identifying which conditions support its upper end.

View model sources →
Not verified
Published area · BasementManufacturer claims with different assumptions are not moisture-load calculations or a cross-brand coverage ranking.1,800–2,200 sq ft · 10 ft ceiling
Notes & sources

Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 1,800–2,200 sq ft sizing range without identifying which conditions support its upper end.

View model sources →
Not verified
Depth including duct collarsIncludes the documented duct collars, but not airflow or service clearance. Missing does not mean no collars.Not verified28 in.
Notes & sources

Includes the documented duct collars, but not airflow or service clearance.

View model sources →
Input power · W65°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.444 W
Notes & sources

PDF p.1 Electrical, Power · Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

View model sources →
Not verified
Running current · A65°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.3.7 A
Notes & sources

PDF p.1 Electrical, Current Draw · Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

View model sources →
Not verified
Input power · W73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.Not verified492 W
Notes & sources

PDF p.1 Electrical, Power · Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

View model sources →
Running current · A73°F · 60% RH · configuration not stated. Manufacturer claims; missing conditions do not imply identical tests.Not verified4.1 A
Notes & sources

PDF p.1 Electrical, Current Draw · Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

View model sources →
Pump hose lengthNot verified
Notes & sources

No included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement.

Not verified
Notes & sources

No included pump discharge-hose length has been verified; gravity-drain tubing is a separate measurement.

Clearance · Return/filter side · filter removalRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.11 in.
Notes & sources

PDF p.5 Location diagram · Diagram shows 11 in for filter removal and return airflow; safety text separately asks for 12 in at return/supply.

View model sources →
Not verified
Clearance · Return side · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.11 in.
Notes & sources

PDF p.5 Location diagram · The 11 in return-side figure differs from the 12 in general safety instruction; do not silently use the smaller value.

View model sources →
Not verified
Clearance · Supply side · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.24 in.
Notes & sources

PDF p.5 Location diagram · Diagram calls for 24 in at the supply outlet, beyond cabinet depth.

View model sources →
Not verified
Clearance · Highest point of drain trap below drain-port adapter · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.2 in.
Notes & sources

PDF p.6 Drain Installation · The highest point of the hose trap must remain at least 2 in below the black drain adapter; trap is positioned 8–10 in from the unit.

View model sources →
Not verified
Clearance · Return side in location diagram · airflowRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6 in.
Notes & sources

PDF p.5 Location diagram · Diagram shows 6 in airflow clearance; conflicts with 12 in safety text.

View model sources →
Clearance · Either filter extraction side · filter removalRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified13 in.
Notes & sources

PDF p.5 Location diagram · Keep 13 in free at the filter-removal side.

View model sources →
Clearance · Drain outlet above floor drain · drainRequirement from the referenced manual and configuration. Do not add cabinet dimensions alone to infer a guaranteed fit.Not verified6.75 in.
Notes & sources

PDF p.7 Drain Installation · Mount so the drain outlet is at least 6.75 in above the floor drain; required trap and supports increase installation height.

View model sources →

The shared number

Both list 70 pints per day at the same warm rating point. Cooler-condition figures use different temperatures, so they are shown separately rather than turned into a score.

The space you actually need

Compact70 is listed at 21 inches deep. Ultra70 is 28 inches with duct collars and 22 inches without them. Both list 12-inch cabinet height and width. Add airflow, service and drain space from the exact manual; the cabinet dimensions alone do not decide the installed footprint.

Reviews & installation evidence

Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.

Article · installation

Compact70 placement: rotatable outlet, hanging kit and controls

Earlier version / historical context: Compact70 described in March 2023; current part 4044110 equivalence not established

Sylvane describes rotating the discharge panel for vertical exhaust and using a separately purchased hanging kit between joists. The article also covers optional ducting and the onboard humidity dial. This is useful when planning access and accessories, but the installation still needs space for ducts, filter removal and a downhill drain. The retailer’s stated coverage is not a sizing guarantee.

Setting / method
Retailer editorial review with placement discussion and published specification tables; no repeatable test protocol or raw results supplied.
What this does not prove
The retailer sells this brand. The 2023 unit is not identified by current part number or refrigerant; measurements, warranty wording and accessory fit must be checked against current documents.
Read the original ↗

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer specSanta Fe Compact70 4044110 Data Sheet TS-2108 Rev B

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2108 Rev B, 01/26
  2. manufacturer specSanta Fe Ultra70 4044100 Specification Sheet TS-2111 Rev B

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2111 Rev B, 01/26
  3. retailerSylvane Reviews: The Santa Fe Compact70 Dehumidifier

    Sylvane · Checked Oct 12, 2026

    Version: Compact70 described in March 2023; current part 4044110 equivalence not established

    External evidence; the summary identifies its scope and limits. Follow the original for the full account.