Documented model profile

Santa Fe Compact70

A 12-inch-high cabinet makes this a candidate for a constrained installation. Its two published capacity figures also show why room temperature belongs in the buying decision.

Model 4044110 · Part 4044110; current product page
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
12 × 12 × 21 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Santa Fe Compact70 — manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
70 pints/day80°F / 60% RH
43.7 pints/day65°F / 60% RH
Drain arrangement
Gravity drainManufacturer manual describes gravity drainage with a required trap; an external pump is optional for a raised destination. Check the full instructions.
Cabinet height
12 in.
Cabinet width
12 in.
Cabinet depth
21 in.
Depth including duct collars
Not verified
Minimum inlet-air temperature
49°F
Noise measurement
Not verifiedComparable independent noise measurements have not been verified.
Duct connection
YesDuct configuration and required accessories must follow the installation manual.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • crawl space1,800–2,600 sq ft

    Manufacturer sizing claim assumes a 5-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 1,800–2,600 sq ft sizing range without identifying which conditions support its upper end.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe; manufacturer PDF hosted by AMGAir ↗
  • basement1,800–2,200 sq ft

    Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 1,800–2,200 sq ft sizing range without identifying which conditions support its upper end.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe; manufacturer PDF hosted by AMGAir ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

  • Input power444 W

    65°F · 60% RH · configuration not stated

    Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

    PDF p.1 Electrical, Power · Santa Fe; manufacturer PDF hosted by AMGAir ↗
  • Running current3.7 A

    65°F · 60% RH · configuration not stated

    Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

    PDF p.1 Electrical, Current Draw · Santa Fe; manufacturer PDF hosted by AMGAir ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
12 ft

Up to 12 ft vertical lift for compatible optional external 4022220 pump; the base Compact 70 has gravity drainage.

Published specification · Santa Fe ↗
Duct collar diameter
8 in.

Optional duct kit uses 8 in return and supply connections. Confirm the ordered kit and included collar configuration.

Published specification · Santa Fe ↗
  • Return/filter side · filter removal11 in.

    Diagram shows 11 in for filter removal and return airflow; safety text separately asks for 12 in at return/supply.

    PDF p.5 Location diagram · Santa Fe ↗
  • Return side · airflow11 in.

    The 11 in return-side figure differs from the 12 in general safety instruction; do not silently use the smaller value.

    PDF p.5 Location diagram · Santa Fe ↗
  • Supply side · airflow24 in.

    Diagram calls for 24 in at the supply outlet, beyond cabinet depth.

    PDF p.5 Location diagram · Santa Fe ↗
  • Return and supply openings · airflow12 in.

    General safety text says 12 in; detailed diagram shows 11 in return and 24 in supply, requiring installer interpretation.

    PDF p.3 Safety Instructions · Santa Fe ↗
  • Highest point of drain trap below drain-port adapter · drain2 in.

    The highest point of the hose trap must remain at least 2 in below the black drain adapter; trap is positioned 8–10 in from the unit.

    PDF p.6 Drain Installation · Santa Fe ↗

General 12 in instruction and detailed 11 in return/24 in supply diagram are preserved separately.

Source discrepancy · Santa Fe ↗

Where it may fit

  • A crawl space installation with a verified drainage and airflow plan.
  • A basement installation with a verified drainage and airflow plan.

Before you buy

  • Allow extra space for airflow, service and the drain connection.
  • Confirm gravity drainage or an external pump in the manual.
  • Current TS-2081 Rev C diagram shows 11-inch return/filter space, while general safety text says 1 foot. Resolve the difference with the manufacturer; do not assume 11 inches is enough.

The tradeoffs

  • Cabinet height is not the minimum installation clearance.
  • Moisture removal drops at the cooler published rating point.

Reviews & installation evidence

Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.

Manufacturer manual · installation

Santa Fe Compact70 Installation & Operation Instructions

Identified model: 4044110; TS-2081 07/24 Rev A

Compact dimensions do not eliminate the need for working space. This manual requires access for filter changes and cabinet removal, a level position and an appropriate drain route. It explains why the drain needs a water trap: unwanted air entering through the hose can interfere with drainage and cause leakage. An external pump is an option when the destination is higher. The manual also distinguishes merely operating down to 49°F from working most effectively above 56°F, and cautions against an aggressive drying setting in colder rooms. For a divided basement, its illustrated supply arrangement includes a return-air path. These details help judge fit before ordering accessories or committing to a location.

Setting / method
Part 4044110; documented current-part installation requirements.
What this does not prove
Manufacturer instructions, not a hands-on performance review. Clearance diagrams and full drain directions must be checked for the actual installation.
Read the original ↗

Article · installation

Compact70 placement: rotatable outlet, hanging kit and controls

Earlier version / historical context: Compact70 described in March 2023; current part 4044110 equivalence not established

Sylvane describes rotating the discharge panel for vertical exhaust and using a separately purchased hanging kit between joists. The article also covers optional ducting and the onboard humidity dial. This is useful when planning access and accessories, but the installation still needs space for ducts, filter removal and a downhill drain. The retailer’s stated coverage is not a sizing guarantee.

Setting / method
Retailer editorial review with placement discussion and published specification tables; no repeatable test protocol or raw results supplied.
What this does not prove
The retailer sells this brand. The 2023 unit is not identified by current part number or refrigerant; measurements, warranty wording and accessory fit must be checked against current documents.
Read the original ↗

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualSanta Fe Compact70 Installation & Operation Instructions

    Santa Fe / Therma-Stor · Checked Oct 12, 2026

    Version: TS-2081 07/24 Rev A; part 4044110
  2. manufacturer manualSanta Fe Compact70 4044110 Installation Instructions TS-2081 Rev C

    Santa Fe / AprilAire official DAM · Checked Oct 12, 2026

    Version: TS-2081 Rev C, 04/26
  3. manufacturer specSanta Fe Compact70 4044110 Data Sheet TS-2108 Rev B

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2108 Rev B, 01/26
  4. manufacturer manualSanta Fe Compact70 4044110 Installation Instructions

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2081 Rev C / 04.26

    Exact 4044110 manual. The diagram calls for 11 inches at the return/filter side and 24 inches at supply; safety text separately says 12 inches at return/supply. The drain trap high point must be at least 2 inches below the drain adapter.

Show 2 more sources
  1. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.

    Alternative source

  2. retailerSylvane Reviews: The Santa Fe Compact70 Dehumidifier

    Sylvane · Checked Oct 12, 2026

    Version: Compact70 described in March 2023; current part 4044110 equivalence not established

    External evidence; the summary identifies its scope and limits. Follow the original for the full account.