Abestorm Guardian SN55S
A gravity-drained 55-pint crawl-space and basement model with documented ducting options. Its current product page and linked R32 sheet disagree about the cabinet dimensions, so a low-clearance fit needs an exact-model drawing.
Model SN55S · SKU RF02ABES-Guardian-SN55S-0NNMG00 · Manufacturer product-page SKU RF02ABES-Guardian-SN55S-0NNMG00; table says R32; installation manual revision unconfirmed
Checked Oct 25, 2026 · current
SKU identifies the gravity-drain SN55S. SNS65/SNS65S is the separate built-in-pump listing. They share ENERGY STAR entry 4005599; the common rating does not describe the different drain equipment.

Product photograph: Abestorm ↗
Check the essentials.
- Extraction rating & conditions
- 55 pints/day80°F / 60% RH · AHAM120 pints/day90°F / 90% RH
- Drain arrangement
- Gravity drainManufacturer-described drainage; complete installation route and manual must be checked.
- Cabinet height
- Not verifiedThe product page and specification sheet give different cabinet sizes: 19.2 × 12.2 × 13.3 in. versus 19.3 × 11.9 × 13.7 in. Confirm the delivered version before assessing fit.
- Cabinet width
- Not verifiedThe product page and specification sheet give different cabinet sizes: 19.2 × 12.2 × 13.3 in. versus 19.3 × 11.9 × 13.7 in. Confirm the delivered version before assessing fit.
- Cabinet depth
- Not verifiedThe product page and specification sheet give different cabinet sizes: 19.2 × 12.2 × 13.3 in. versus 19.3 × 11.9 × 13.7 in. Confirm the delivered version before assessing fit.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 33.8°FManufacturer specification; no independent measurement.
- Power at published conditions
- Not verified
- Duct connection
- YesThe linked exact-model manufacturer specification explicitly describes optional duct mounting and a ducted installation. Confirm the matching collar kit and installed airflow requirements.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Certified efficiency & annual energy
ENERGY STAR V6 ratings use DOE test configurations: whole-home at 73°F / 60% RH, portable at 65°F / 60% RH. The registry’s “portable” category describes the test setup; it does not imply a water bucket. Compare IEF within the same configuration.
1 of 1 selected profiles have a matched active registry entry. Missing entries do not prove that other models were never certified.
Abestorm Guardian SN55S
Portable test · 65°F / 60% RH · HFC-32
Family rating shared with SNS65 →
The shared test entry does not distinguish pump equipment or establish identical hardware.
- Certified water removal
- 36.33 pints/day
- Integrated energy factor
- 2.08 L/kWh
- Reported annual energy
- 379 kWh/year
- Annual cost illustration
- $75.80
ENERGY STAR partner: AlorAir Solutions Inc.
Exact primary model number in the active registry. Rating conditions come from the declared test configuration and Appendix X1. This is a standardized certification rating, not an independent home test or an operating watt measurement. This is a family entry with an explicitly named additional model; the rating alone does not distinguish pump equipment. Both the ALORAIR and ABESTORM entries name AlorAir Solutions Inc. as their ENERGY STAR partner. This does not establish identical hardware or interchangeable parts.
Registry ID 4005599 · Guardian SN55S ↗Cost illustration = reported annual kWh × your tariff. ENERGY STAR’s annual method uses 1,095 dehumidification hours plus low-power energy. It is not a prediction for your moisture load, settings or installation, and IEF is not operating watts. Read the annual method ↗
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 1,300 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · Abestorm ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Sound level50 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.
Product-page specification table: Sound Pressure Level(dBa) · Abestorm ↗ - Running current4.1 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.
PDF p1, current/power specification row · Abestorm ↗ - Sound level< 52 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.
PDF p1, sound-pressure specification row · Abestorm ↗ - Running current4 A
temperature not stated · humidity not stated · configuration not stated
The same linked R32 sheet prints 4.1 A in its specification area and 4.0 A in a paragraph still describing a 53-pint claim. A single current value is not selected.
PDF p1, visible Proven Performance paragraph · Abestorm ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Air inlet (linked manual) · airflow72 in.
The linked SN55S manual prints 6 feet at both openings, equivalent to 72 inches. This records the printed requirement; confirm its intended clearance and delivered revision with Abestorm before installation. It is not a six-inch value.
PDF p.3 / printed p.2, Safety Notes; feet mark at both openings · Abestorm ↗ - Air discharge (linked manual) · airflow72 in.
The linked SN55S manual prints 6 feet at both openings, equivalent to 72 inches. This records the printed requirement; confirm its intended clearance and delivered revision with Abestorm before installation. It is not a six-inch value.
PDF p.3 / printed p.2, Safety Notes; feet mark at both openings · Abestorm ↗
Linked manual specifies a 6-inch supply grille and a 6-foot duct run. Current-generation collar compatibility needs confirmation; do not infer a return port of this size.
Ducted Applications (HD55/HD55S printed p9; HDi65S printed p9; SN55S printed p9) · Abestorm ↗Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.
Measurement source discrepancy · Abestorm ↗Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.
Measurement source discrepancy · Abestorm ↗ / Abestorm ↗Where it may fit
- Comparing manufacturer-documented crawl-space, basement options for a matching installation.
Before you buy
- Confirm exact SKU and generation against the current installation manual.
- Check access dimensions, operating conditions and the complete drain route before purchase.
The tradeoffs
- The product page and specification sheet give different cabinet sizes: 19.2 × 12.2 × 13.3 in. versus 19.3 × 11.9 × 13.7 in. Confirm the delivered version before assessing fit.
Reviews & installation evidence
Manufacturer product pages, linked manuals and available specification sheets reviewed October 25, 2026. Conflicting generations and dimensions remain explicit; no independent product test is claimed.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer manualAbestorm Guardian SN55S linked installation and operation manual
Abestorm · Checked Oct 25, 2026
Version: Linked manual, filename 20241227The linked SN55S manual prints 6 feet at both air openings. Confirm that requirement and the delivered revision with the manufacturer; do not substitute six inches.
- manufacturer productAbestorm Guardian SN55S manufacturer product page
Abestorm · Checked Oct 25, 2026
- manufacturer specAbestorm Guardian SN55S current linked specification sheet
Abestorm · Checked Oct 25, 2026
Version: File identifier 20251222 - official guidanceDOE Appendix X1: dehumidifier test method
eCFR / U.S. Department of Energy · Checked Oct 12, 2026
Version: Current text, title updated through 2026-10-08Standard rating conditions differ by configuration. IEF includes low-power modes and is not operating input watts.
Show 3 more sources
- official guidanceENERGY STAR registry: ABESTORM Guardian SN55S (ID 4005599)
EPA ENERGY STAR · Checked Oct 12, 2026
Version: V6 registry ID 4005599; HFC-32Registry ratings apply to the named configuration and refrigerant; confirm the delivered model label.
- official guidanceENERGY STAR dehumidifier specification: Version 6 final
EPA ENERGY STAR · Checked Oct 12, 2026
Version: Final V6, effective October 1, 2025Annual consumption is a standardized test-based estimate using1095 annual dehumidification hours and low-power energy. It does not predict a particular household bill.
- official guidanceENERGY STAR certified dehumidifiers: active Version 6 dataset
EPA ENERGY STAR · Checked Oct 12, 2026
Version: Active V6 dataset, retrieved 2026-10-12Certification entries use exact names and configurations. Absence from this snapshot does not prove that a product has never been certified.