Documented model profile
Abestorm Guardian SN90
Abestorm markets the Guardian SN90 for crawl spaces and basements. Its 90-pint AHAM claim is recorded separately from its 198-pint saturation output. It uses gravity drainage.
Model SN90 · Manufacturer product-page SKU RF02ABES-Guardian-SN90-0NNMG00; table says R32; installation manual revision unconfirmed
Checked Oct 12, 2026 · current

Product photograph: Abestorm ↗
Check the essentials.
- Extraction rating & conditions
- 90 pints/day80°F / 60% RH · AHAM198 pints/day90°F / 90% RH
- Drain arrangement
- Gravity drainManufacturer-described drainage; complete installation route and manual must be checked.
- Cabinet height
- 16.4 in.Product page states 16.4-inch height and the linked current R32 front-view dimension drawing agrees. The PDF scalar table mislabels horizontal axis order; allow added installation space.
- Cabinet width
- 14 in.Manufacturer specification; no independent measurement.
- Cabinet depth
- 22 in.Manufacturer specification; no independent measurement.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 33.8°FManufacturer specification; no independent measurement.
- Power at published conditions
- Not verified
- Duct connection
- YesThe linked exact-model manufacturer specification explicitly describes optional duct mounting and a ducted installation. Confirm the matching collar kit and installed airflow requirements.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 2,600 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · Abestorm ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Sound level58 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.
Product-page specification table: Sound Pressure Level(dBa) · Abestorm ↗ - Running current5.56 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.
PDF p1, current/power specification row · Abestorm ↗ - Sound level< 58 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.
PDF p1, sound-pressure specification row · Abestorm ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.
Measurement source discrepancy · Abestorm ↗ / Abestorm ↗Where it may fit
- Comparing manufacturer-documented crawl-space, basement options for a matching installation.
Before you buy
- Confirm exact SKU and generation against the current installation manual.
- Check access dimensions, operating conditions and the complete drain route before purchase.
The tradeoffs
- The PDF scalar dimension table has an axis-label error; use its drawing for cabinet height and confirm the exact horizontal footprint. The body contains stray pump wording although product drainage is gravity.
Reviews & installation evidence
Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer manualAbestorm Guardian SN90 linked installation and operation manual
Abestorm · Checked Oct 12, 2026
Version: Linked manual, filename 20250430Exact model manual currently linked by the manufacturer; match the delivered model plate and document revision before installation.
- manufacturer productAbestorm Guardian SN90 manufacturer product page
Abestorm · Checked Oct 12, 2026
- manufacturer specAbestorm Guardian SN90 current linked specification sheet
Abestorm · Checked Oct 12, 2026
Version: File identifier 20251011