Documented model profile

Abestorm Guardian SN90

Abestorm markets the Guardian SN90 for crawl spaces and basements. Its 90-pint AHAM claim is recorded separately from its 198-pint saturation output. It uses gravity drainage.

Model SN90 · Manufacturer product-page SKU RF02ABES-Guardian-SN90-0NNMG00; table says R32; installation manual revision unconfirmed
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
14 × 16.4 × 22 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Abestorm Guardian SN90 — manufacturer product photograph

Product photograph: Abestorm ↗

Check the essentials.

Extraction rating & conditions
90 pints/day80°F / 60% RH · AHAM
198 pints/day90°F / 90% RH
Drain arrangement
Gravity drainManufacturer-described drainage; complete installation route and manual must be checked.
Cabinet height
16.4 in.Product page states 16.4-inch height and the linked current R32 front-view dimension drawing agrees. The PDF scalar table mislabels horizontal axis order; allow added installation space.
Cabinet width
14 in.Manufacturer specification; no independent measurement.
Cabinet depth
22 in.Manufacturer specification; no independent measurement.
Depth including duct collars
Not verified
Minimum inlet-air temperature
33.8°FManufacturer specification; no independent measurement.
Power at published conditions
Not verified
Duct connection
YesThe linked exact-model manufacturer specification explicitly describes optional duct mounting and a ducted installation. Confirm the matching collar kit and installed airflow requirements.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • Manufacturer area statementUp to 2,600 sq ft

    Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.

    Exact model product description / specifications: floor area or Size for · Abestorm ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.

  • Sound level58 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.

    Product-page specification table: Sound Pressure Level(dBa) · Abestorm ↗
  • Running current5.56 A

    temperature not stated · humidity not stated · configuration not stated

    Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.

    PDF p1, current/power specification row · Abestorm ↗
  • Sound level< 58 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.

    PDF p1, sound-pressure specification row · Abestorm ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.

Measurement source discrepancy · Abestorm ↗ / Abestorm ↗

Where it may fit

  • Comparing manufacturer-documented crawl-space, basement options for a matching installation.

Before you buy

  • Confirm exact SKU and generation against the current installation manual.
  • Check access dimensions, operating conditions and the complete drain route before purchase.

The tradeoffs

  • The PDF scalar dimension table has an axis-label error; use its drawing for cabinet height and confirm the exact horizontal footprint. The body contains stray pump wording although product drainage is gravity.

Reviews & installation evidence

Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.

We are collecting relevant tests, installations and owner experience for this exact version.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualAbestorm Guardian SN90 linked installation and operation manual

    Abestorm · Checked Oct 12, 2026

    Version: Linked manual, filename 20250430

    Exact model manual currently linked by the manufacturer; match the delivered model plate and document revision before installation.

  2. manufacturer productAbestorm Guardian SN90 manufacturer product page

    Abestorm · Checked Oct 12, 2026

  3. manufacturer specAbestorm Guardian SN90 current linked specification sheet

    Abestorm · Checked Oct 12, 2026

    Version: File identifier 20251011