Documented model profile
Abestorm Guardian SNS100
Abestorm markets the Guardian SNS100 for crawl spaces and basements. Its 100-pint AHAM claim is recorded separately from its 220-pint saturation output. It has a built-in condensate pump.
Model SNS100 · Manufacturer product-page SKU RF02ABES-Guardian-SNS100-0YAMG00; table says R32; installation manual revision unconfirmed
Checked Oct 12, 2026 · current

Product photograph: Abestorm ↗
Check the essentials.
- Extraction rating & conditions
- 100 pints/day80°F / 60% RH · AHAM220 pints/day90°F / 90% RH
- Drain arrangement
- Built-in pumpManufacturer-described drainage; complete installation route and manual must be checked.
- Cabinet height
- 17.9 in.Manufacturer specification; no independent measurement.
- Cabinet width
- 14.7 in.Manufacturer specification; no independent measurement.
- Cabinet depth
- 23.8 in.Manufacturer specification; no independent measurement.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 33.8°FManufacturer specification; no independent measurement.
- Power at published conditions
- Not verified
- Duct connection
- Not verified
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 2,900 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · Abestorm ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Sound level60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.
Product-page specification table: Sound Pressure Level(dBa) · Abestorm ↗ - Running current6.82 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.
PDF p1, current/power specification row · Abestorm ↗ - Sound level< 60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.
PDF p1, sound-pressure specification row · Abestorm ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Built-in pump · published lift
- 14.7 ft
Explicit manufacturer vertical-lift/drain-height claim for this listing. Confirm the exact model, tubing route and hydraulic limits in the delivered-unit manual; no independent pump test is claimed.
Published specification · Abestorm ↗ - Pump hose length
- 19.6 ft
Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.
Published specification · Abestorm ↗
Earlier R410A manual specifies 10-inch supply and return flex duct. It is not automatically a verified size for current R32 hardware.
PDF p12 / printed p10, Ducted Applications · Abestorm ↗Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.
Measurement source discrepancy · Abestorm ↗ / Abestorm ↗Where it may fit
- Comparing manufacturer-documented crawl-space, basement options for a matching installation.
Before you buy
- Confirm exact SKU and generation against the current installation manual.
- Check access dimensions, operating conditions and the complete drain route before purchase.
The tradeoffs
- Verify the current installation manual, clearances and complete drain route; product-page figures are not independent measurements.
Reviews & installation evidence
Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer manualAbestorm Guardian SNS100 linked installation and operation manual
Abestorm · Checked Oct 12, 2026
Version: R410A manual; earlier generationThis linked manual explicitly describes R410A hardware. Its installation dimensions and accessories cannot automatically be applied to the current R32 listing.
- manufacturer productAbestorm Guardian SNS100 manufacturer product page
Abestorm · Checked Oct 12, 2026
- manufacturer specAbestorm Guardian SNS100 current linked specification sheet
Abestorm · Checked Oct 12, 2026
Version: File identifier 20221222