Documented model profile

Abestorm Guardian SNS120

A pump-equipped 120-pint-rated Guardian intended for crawl spaces, basements and ducted whole-home installations. Current manufacturer sources disagree on cabinet dimensions and AHAM temperature, so verify the exact model drawing before sizing a tight installation.

Model SNS120 · Manufacturer product-page SKU RF02ABES-Guardian-SNS120-0YAMG00; table says R32; installation manual revision unconfirmed
Checked Oct 25, 2026 · current

Can I use it here?

Cabinet (W × H × D)
Confirm the cabinet dimensions
Drain
Built-in pump · Confirm the pump lift
See prices, stores and buying notes ↓
Abestorm Guardian SNS120 — manufacturer product photograph

Product photograph: Abestorm ↗

Check the essentials.

Extraction rating & conditions
120 pints/dayTest conditions not verified · AHAM
235 pints/day90°F / 90% RH
Drain arrangement
Built-in pumpManufacturer-described drainage; complete installation route and manual must be checked.
Cabinet height
Not verifiedManufacturer documents give different cabinet sizes: 23.82 × 13.98 × 15.94 in. versus 23.8 × 14.7 × 17.9 in. Confirm a drawing for the delivered version.
Cabinet width
Not verifiedManufacturer documents give different cabinet sizes: 23.82 × 13.98 × 15.94 in. versus 23.8 × 14.7 × 17.9 in. Confirm a drawing for the delivered version.
Cabinet depth
Not verifiedManufacturer documents give different cabinet sizes: 23.82 × 13.98 × 15.94 in. versus 23.8 × 14.7 × 17.9 in. Confirm a drawing for the delivered version.
Depth including duct collars
Not verified
Minimum inlet-air temperature
33.8°FManufacturer operating range starts at 33.8°F. Output at the lower end is not specified by this limit.
Power at published conditions
Not verified
Duct connection
YesManufacturer specification; no independent measurement.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • Manufacturer area statementUp to 3,300 sq ft

    Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.

    Exact model product description / specifications: floor area or Size for · Abestorm ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.

  • Sound level60 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.

    Product-page specification table: Sound Pressure Level(dBa) · Abestorm ↗
  • Running current7.8 A

    temperature not stated · humidity not stated · configuration not stated

    Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.

    PDF p1, current/power specification row · Abestorm ↗
  • Sound level< 60 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.

    PDF p1, sound-pressure specification row · Abestorm ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Pump hose length
19.6 ft

Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.

Published specification · Abestorm ↗
Pump lift needs confirmation

The sources do not establish one reliable maximum for this exact version.

  • 14.7 ft · Description claims a 14.7-foot lift but the specification table leaves Drain Height blank and current case dimensions disagree across documents. It is retained as a reading, not a single verified generation limit.Product Description, lifting capacity · Abestorm ↗

Earlier R410A manual specifies 10-inch supply and return flex duct. It is not automatically a verified size for current R32 hardware.

PDF p12 / printed p10, Ducted Applications · Abestorm ↗

Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.

Measurement source discrepancy · Abestorm ↗ / Abestorm ↗

The still-linked manual names R410A, while the current product table and specification sheet name R32. Its cabinet, airflow-clearance and electrical values are not treated as confirmed requirements for the R32 unit; obtain the matching current manual.

Linked manual PDF p.4 / printed p.3 Specifications and Installation Requirements; current R32 product table and specification sheet · Abestorm ↗ / Abestorm ↗ / Abestorm ↗

Where it may fit

  • Comparing manufacturer-documented crawl-space, basement options for a matching installation.

Before you buy

  • Confirm exact SKU and generation against the current installation manual.
  • Check access dimensions, operating conditions and the complete drain route before purchase.

The tradeoffs

  • Manufacturer documents list different minimum temperatures, 33.8°F and 36°F. Confirm the operating range for the delivered version.
  • Manufacturer documents give different cabinet sizes: 23.82 × 13.98 × 15.94 in. versus 23.8 × 14.7 × 17.9 in. Confirm a drawing for the delivered version.

Reviews & installation evidence

Manufacturer product pages, linked manuals and available specification sheets reviewed October 25, 2026. Conflicting generations and dimensions remain explicit; no independent product test is claimed.

We are collecting relevant tests, installations and owner experience for this exact version.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualAbestorm Guardian SNS120 linked installation and operation manual

    Abestorm · Checked Oct 25, 2026

    Version: R410A manual; earlier generation

    The current listing is R32, while this still-linked manual identifies R410A. Its cabinet and installation values are not assigned to the R32 profile.

  2. manufacturer productAbestorm Guardian SNS120 manufacturer product page

    Abestorm · Checked Oct 25, 2026

  3. manufacturer specAbestorm Guardian SNS120 current linked specification sheet

    Abestorm · Checked Oct 25, 2026

    Version: File identifier 20251222