Documented model profile

AlorAir Sentinel HDi100

The HDi100 catalog separates a 100-pint AHAM rating from a 220-pint saturation claim. It uses pump drainage and a larger chassis than the smaller Sentinel units; the installed footprint and discharge route need checking.

Model HDi100 · Current product-page model with R32 specification PDF dated in filename 20251219; exact delivered production SKU must be checked
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
14.7 × 17.9 × 23.8 in.
Drain
Built-in pump · Confirm the pump lift
See prices, stores and buying notes ↓
AlorAir Sentinel HDi100 — manufacturer product photograph

Product photograph: AlorAir ↗

Check the essentials.

Extraction rating & conditions
100 pints/day80°F / 60% RH · Manufacturer AHAM label
78 pints/day73°F / 60% RH · Manufacturer DOE label
220 pints/dayTest conditions not verified
Drain arrangement
Built-in pumpPump and/or gravity mode as stated in the named product specification; mode and hose setup must be checked in the exact manual.
Cabinet height
17.9 in.Manufacturer product specification; not independently measured.
Cabinet width
14.7 in.Manufacturer product specification; not independently measured.
Cabinet depth
23.8 in.Manufacturer product specification; not independently measured.
Depth including duct collars
Not verified
Minimum inlet-air temperature
33.8°FManufacturer product specification; not independently measured.
Power at published conditions
Not verified
Duct connection
YesR32 specification explicitly supports ducting to an HVAC system with optional mounting flanges; installation design and the exact kit remain separate checks.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • Manufacturer area statementUp to 2,900 sq ft

    Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.

    Exact model product description / specifications: floor area or Size for · AlorAir ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.

  • Sound level60 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.

    Product-page specification table: Sound pressure level · AlorAir ↗
  • Running current6.82 A

    temperature not stated · humidity not stated · configuration not stated

    Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.

    PDF p1, current/power specification row · AlorAir ↗
  • Sound level< 60 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.

    PDF p1, sound-pressure specification row · AlorAir ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Pump hose length
19.6 ft

Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.

Published specification · AlorAir ↗

Earlier R410A manual specifies 10-inch supply and return flex duct. It is not automatically a verified size for current R32 hardware.

PDF p12 / printed p10, Ducted Applications · AlorAir ↗

Manufacturer documents give different values or bounds. Show source-specific readings; do not substitute a single supposedly measured scalar.

Measurement source discrepancy · AlorAir ↗ / AlorAir ↗

Where it may fit

  • Comparing dedicated pump-equipped units for a sealed crawl space or basement.

Before you buy

  • Confirm the exact current SKU, refrigerant generation and matching installation manual.
  • Verify access clearance and the complete condensate-discharge route before ordering.

The tradeoffs

  • Current R32 specification lists different capacity points for 80°F/60% RH and 73°F/60% RH; compare equal conditions. Check duct collars, air path and pump discharge requirements separately.

Reviews & installation evidence

Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.

We are collecting relevant tests, installations and owner experience for this exact version.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer productAlorAir crawl-space, basement and whole-house catalog

    AlorAir · Checked Oct 11, 2026

  2. manufacturer manualAlorAir Sentinel HDi100 linked installation and operation manual

    AlorAir · Checked Oct 12, 2026

    Version: R410A manual; earlier generation

    This linked manual explicitly describes R410A hardware. Its installation dimensions and accessories cannot automatically be applied to the current R32 listing.

  3. manufacturer productAlorAir Sentinel HDi100 manufacturer product page

    AlorAir · Checked Oct 12, 2026

  4. manufacturer specAlorAir Sentinel HDi100 current linked specification sheet

    AlorAir · Checked Oct 12, 2026

    Version: File identifier 20251219