Documented model profile
AlorAir Sentinel HDi100
The HDi100 catalog separates a 100-pint AHAM rating from a 220-pint saturation claim. It uses pump drainage and a larger chassis than the smaller Sentinel units; the installed footprint and discharge route need checking.
Model HDi100 · Current product-page model with R32 specification PDF dated in filename 20251219; exact delivered production SKU must be checked
Checked Oct 12, 2026 · current

Check the essentials.
- Extraction rating & conditions
- 100 pints/day80°F / 60% RH · Manufacturer AHAM label78 pints/day73°F / 60% RH · Manufacturer DOE label220 pints/dayTest conditions not verified
- Drain arrangement
- Built-in pumpPump and/or gravity mode as stated in the named product specification; mode and hose setup must be checked in the exact manual.
- Cabinet height
- 17.9 in.Manufacturer product specification; not independently measured.
- Cabinet width
- 14.7 in.Manufacturer product specification; not independently measured.
- Cabinet depth
- 23.8 in.Manufacturer product specification; not independently measured.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 33.8°FManufacturer product specification; not independently measured.
- Power at published conditions
- Not verified
- Duct connection
- YesR32 specification explicitly supports ducting to an HVAC system with optional mounting flanges; installation design and the exact kit remain separate checks.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 2,900 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · AlorAir ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Sound level60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.
Product-page specification table: Sound pressure level · AlorAir ↗ - Running current6.82 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.
PDF p1, current/power specification row · AlorAir ↗ - Sound level< 60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.
PDF p1, sound-pressure specification row · AlorAir ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Pump hose length
- 19.6 ft
Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.
Published specification · AlorAir ↗
Earlier R410A manual specifies 10-inch supply and return flex duct. It is not automatically a verified size for current R32 hardware.
PDF p12 / printed p10, Ducted Applications · AlorAir ↗Where it may fit
- Comparing dedicated pump-equipped units for a sealed crawl space or basement.
Before you buy
- Confirm the exact current SKU, refrigerant generation and matching installation manual.
- Verify access clearance and the complete condensate-discharge route before ordering.
The tradeoffs
- Current R32 specification lists different capacity points for 80°F/60% RH and 73°F/60% RH; compare equal conditions. Check duct collars, air path and pump discharge requirements separately.
Reviews & installation evidence
Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer productAlorAir crawl-space, basement and whole-house catalog
AlorAir · Checked Oct 11, 2026
- manufacturer manualAlorAir Sentinel HDi100 linked installation and operation manual
AlorAir · Checked Oct 12, 2026
Version: R410A manual; earlier generationThis linked manual explicitly describes R410A hardware. Its installation dimensions and accessories cannot automatically be applied to the current R32 listing.
- manufacturer productAlorAir Sentinel HDi100 manufacturer product page
AlorAir · Checked Oct 12, 2026
- manufacturer specAlorAir Sentinel HDi100 current linked specification sheet
AlorAir · Checked Oct 12, 2026
Version: File identifier 20251219