AlorAir Sentinel HDi120
A larger pump-equipped Sentinel model whose catalog lists 120 pints per day at AHAM and 235 pints at saturation. The manufacturer describes ductable use, but the appropriate kit and rated installation conditions still need verification.
Model HDi120 · Current product-page model with R32 specification PDF dated in filename 20251219; exact delivered production SKU must be checked
Checked Oct 12, 2026 · current

Check the essentials.
- Extraction rating & conditions
- 120 pints/day80°F / 60% RH · Manufacturer AHAM label93 pints/day73°F / 60% RH · Manufacturer DOE label235 pints/dayTest conditions not verified
- Drain arrangement
- Built-in pumpPump and/or gravity mode as stated in the named product specification; mode and hose setup must be checked in the exact manual.
- Cabinet height
- 17.9 in.Manufacturer product specification; not independently measured.
- Cabinet width
- 14.7 in.Manufacturer product specification; not independently measured.
- Cabinet depth
- 23.8 in.Manufacturer product specification; not independently measured.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 33.8°FManufacturer product specification; not independently measured.
- Power at published conditions
- Not verified
- Duct connection
- YesR32 specification explicitly supports ducting to an HVAC system with optional mounting flanges; installation design and the exact kit remain separate checks.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 3,300 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · AlorAir ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Running current7.8 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed current; test conditions and compressor starting current are not supplied. Wattage cannot be calculated from this value alone.
Product-page specification table: Current · AlorAir ↗ - Sound level60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.
Product-page specification table: Sound Pressure level · AlorAir ↗ - Running current7.8 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.
PDF p1, current/power specification row · AlorAir ↗ - Sound level< 60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.
PDF p1, sound-pressure specification row · AlorAir ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Pump hose length
- 19.6 ft
Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.
Published specification · AlorAir ↗
Earlier R410A manual specifies 10-inch supply and return flex duct. It is not automatically a verified size for current R32 hardware.
PDF p12 / printed p10, Ducted Applications · AlorAir ↗Where it may fit
- Comparing dedicated pump-equipped units for a sealed crawl space or basement.
Before you buy
- Confirm the exact current SKU, refrigerant generation and matching installation manual.
- Verify access clearance and the complete condensate-discharge route before ordering.
The tradeoffs
- Current R32 specification lists different capacity points for 80°F/60% RH and 73°F/60% RH; compare equal conditions. Check duct collars, air path and pump discharge requirements separately.
Reviews & installation evidence
Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer productAlorAir crawl-space, basement and whole-house catalog
AlorAir · Checked Oct 11, 2026
- manufacturer manualAlorAir Sentinel HDi120 linked installation and operation manual
AlorAir · Checked Oct 12, 2026
Version: R410A manual; earlier generationThis linked manual explicitly describes R410A hardware. Its installation dimensions and accessories cannot automatically be applied to the current R32 listing.
- manufacturer productAlorAir Sentinel HDi120 manufacturer product page
AlorAir · Checked Oct 12, 2026
- manufacturer specAlorAir Sentinel HDi120 current linked specification sheet
AlorAir · Checked Oct 12, 2026
Version: File identifier 20251219