AprilAire E050
A small R32 cabinet for crawl spaces, smaller basements and rooms. The actual listed height is 9.86 in, with 50, 42 and 35 pints/day at 80, 73 and 65°F respectively, all at 60% RH. Optional collars permit ducting; water drains by gravity or through an added external pump.
Model E050 · Current R32 non-Wi-Fi E050 model; primary Form 1008 326107 • 07.25
Checked Oct 12, 2026 · current

Product photograph: AprilAire ↗
Check the essentials.
- Extraction rating & conditions
- 50 pints/day80°F / 60% RH42 pints/day73°F / 60% RH35 pints/day65°F / 60% RH
- Drain arrangement
- Gravity drainManufacturer describes drainage to a common floor or waste drain. The 4856 condensate pump is an optional external accessory, not a built-in pump.
- Cabinet height
- 9.86 in.Cabinet-only measurement; excludes adjustable feet, filter-door/user-interface protrusions and duct collars. Check service clearance separately. Product actual height 9.86 in versus rounded 10 in spec table; detailed spec drawing also 9.86 in.
- Cabinet width
- 9.71 in.Cabinet-only measurement; excludes adjustable feet, filter-door/user-interface protrusions and duct collars. Check service clearance separately. Product actual width 9.71 in versus rounded 10 in spec table; detailed drawing also 9.71 in.
- Cabinet depth
- 25 in.Cabinet-only measurement; excludes adjustable feet, filter-door/user-interface protrusions and duct collars. Check service clearance separately.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 50°FDehumidification inlet air 50–104°F with minimum 40°F dew point. Lower ventilation-only limit is not dehumidification capability.
- Duct connection
- YesExact-model specification includes ducted application. E050 8-inch collar kit is optional; other models have their listed collars.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 1,600 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · AprilAire ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
- Running current4.2 A
80°F · 60% RH · configuration not stated
Manufacturer rated current at 80°F/60% RH inlet air and 0.0 external static pressure. This is current, not input watts or a starting-surge value.
PDF p.1 Specifications, Current Draw and rating footnote · AprilAire ↗ - Sound level54 dBA
temperature not stated · humidity not stated · ducted · distance not stated
Manufacturer sound rating for ducted installation. Distance, temperature, humidity and acoustic test method are not given; it is not an independent comparison.
PDF p.1 Specifications, Noise row · AprilAire ↗ - Sound level57 dBA
temperature not stated · humidity not stated · unducted · distance not stated
Manufacturer unducted sound rating; measuring distance and acoustic test conditions are not stated.
PDF p.1 Noise row · AprilAire ↗ - Standby power< 3 W
temperature not stated · humidity not stated · standby
Idle only: manufacturer says less than 3 W when both fan and compressor are stopped. This is not operating input power.
PDF p.4 Operating the Dehumidifier / idle power · AprilAire ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Optional external pump · published lift
- 22 ft
Up to 22 feet lift for separately purchased AprilAire 4856 condensate pump. The base dehumidifier drains by gravity and does not contain this pump.
Published specification · AprilAire ↗ - Duct collar diameter
- 8 in.
8-inch inlet and outlet connections. E050 collars are separately purchased optional accessories.
Published specification · AprilAire ↗
- First straight section after the outlet collar · airflow4 in.
Keep the first 4 inches of outlet duct free of bends. This is a straight-duct requirement, not a general wall clearance.
PDF p.6 Installing Duct Collars · AprilAire ↗
Ducted whole-home use requires an air-conditioned installation space to reduce exterior condensation. The manual cautions against unconditioned attics, basements and similar locations for this application.
PDF pp.6–7 Whole-home application caution · AprilAire ↗The service-side panel must remain removable for electrical access and drain cleaning; no numerical service clearance is given.
PDF p.6 Dehumidifier Location · AprilAire ↗Where it may fit
- Low-cabinet installations where a 50-pint 80°F rating and smaller-space application fit the moisture load.
- Installations with a documented gravity drain or room for a separately purchased condensate pump.
Before you buy
- Check the exact model suffix and the installation envelope, including feet, duct collars, filter removal and the drain route.
- Ask the seller or installer to confirm the current revision, included parts and warranty. Manufacturer listing directs buyers to Healthy Air Professionals.
The tradeoffs
- Cabinet measurements do not include the full installation or filter-service envelope.
- E050 collars are optional; the 10 in shorthand cabinet size does not include feet or ducting. Current product warranty terms differ from older manuals.
Reviews & installation evidence
Manufacturer product page and linked primary documents checked 2026-10-11. We have not independently measured performance, noise, reliability or installation results.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer manualAprilAire E050 installation and owner manual 10017311
AprilAire · Checked Oct 12, 2026
Version: 10017311A • 09.24 - manufacturer productAprilAire E050 manufacturer product page
AprilAire · Checked Oct 12, 2026
- manufacturer specAprilAire E050 specification Form 1008
AprilAire · Checked Oct 12, 2026
Version: Form 1008 • 326107 • 07.25