Documented model profile

Santa Fe Advance Dry110

Part 4047010 is a R454B Advance Dry 110 with 110 pints/day at 80°F/60% RH and 70 at 65°F/60% RH. Its 24 in cabinet and dual outlets suit roomy basement or crawl-space installations; drainage uses an internal ball trap or a separately arranged external P-trap, plus an optional external pump.

Model Advance Dry110 / 4047010 · Current R454B part 4047010; TS-2135 04/26 Rev E
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
14.35 × 24 × 29 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Santa Fe Advance Dry110 current manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
110 pints/day80°F / 60% RH
70 pints/day65°F / 60% RH
Drain arrangement
Gravity drainCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
Cabinet height
24 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet width
14.35 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet depth
29 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Depth including duct collars
Not verified
Minimum inlet-air temperature
40°FManufacturer exact-part specification; no independent measurement.
Noise measurement
Not verified
Duct connection
YesManufacturer specification; no independent measurement.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • crawl spaceUp to 3,600 sq ft

    The sheet lists area and cubic-foot estimates that do not reconcile with its ceiling footnote. Confirm sizing assumptions before using this claim.

    Sizing assumptions need clarification; this claim cannot confirm an area match.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗
  • basementUp to 2,900 sq ft

    The sheet lists area and cubic-foot estimates that do not reconcile with its ceiling footnote. Confirm sizing assumptions before using this claim.

    Sizing assumptions need clarification; this claim cannot confirm an area match.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

  • Input power480 W

    65°F · 60% RH · configuration not stated

    Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

    PDF p.1 Electrical, Power · Santa Fe ↗
  • Running current4.1 A

    65°F · 60% RH · configuration not stated

    Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

    PDF p.1 Electrical, Current Draw · Santa Fe ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
12 ft

The exact current model product page links the optional external condensate-pump kit and states up to 12 ft vertical lift. This is a separately purchased accessory, not a built-in pump; confirm the installer package and route.

Published specification · Santa-Fe ↗ / Santa Fe ↗
Duct collar diameter
10 in.

Optional 10-inch duct collars attach to one or both supply outlets; use the included blanking plate when needed. This does not identify a ducted return connection.

Published specification · Santa Fe ↗
  • Return and supply openings · airflow12 in.

    Safety text requires 12 in, while location diagram shows 6 in; obtain clarification before a tight installation.

    PDF p.3 Safety Instructions · Santa Fe ↗
  • Return-air side in location diagram · airflow6 in.

    Diagram shows 6 in for airflow, conflicting with 12 in safety text.

    PDF p.5 Location Considerations diagram · Santa Fe ↗
  • Either filter extraction side · filter removal15 in.

    Leave at least 15 in for filter extraction on the chosen side.

    PDF p.5 Location Considerations diagram · Santa Fe ↗

Safety section asks for 12 in; the location diagram shows 6 in. Both manufacturer statements are retained.

Source discrepancy · Santa Fe ↗

Where it may fit

  • A basement or roomy crawl space where divided-area airflow and the required trap/service space can be arranged.

Before you buy

  • Check that the seller supplies the exact current part number and R454B generation shown here.
  • Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.
  • Select the documented built-in ball-trap arrangement or external P-trap arrangement; they have different elevation needs. TS2135 contains apparent Dry 100 naming typos inside the Dry 110 manual.

The tradeoffs

  • Capacity depends on inlet conditions; a rated floor area is not a guaranteed match for an unsealed or actively leaking space.

Reviews & installation evidence

Current manufacturer product page, exact-part R454B specification and available current installation manual checked 2026-10-11. We have not independently tested this device.

We are collecting relevant tests, installations and owner experience for this exact version.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer productSanta Fe Advance Dry110 manufacturer product page

    Santa-Fe · Checked Oct 12, 2026

    Alternative source

  2. manufacturer specSanta Fe Advance Dry110 4047010 manufacturer specification TS-2136

    Santa Fe · Checked Oct 12, 2026

  3. manufacturer manualSanta Fe TS-2135 04/26 Rev E installation and operation manual

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2135 04/26 Rev E
  4. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.

    Alternative source