Documented model profile
Santa Fe Classic
The current R454B Classic 4044710 has a 36 in vertical cabinet and a 116 pint 80°F/60% RH rating, falling to 76 pints at 65°F/60% RH. It drains through a downward-sloped hose, with a separate optional pump for lift and optional duct kits for airflow distribution.
Model Classic / 4044710 · Current R454B part 4044710; TS-2095 04/26 Rev C
Checked Oct 12, 2026 · current

Product photograph: Santa Fe ↗
Check the essentials.
- Extraction rating & conditions
- 116 pints/day80°F / 60% RH76 pints/day65°F / 60% RH
- Drain arrangement
- Gravity drainCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
- Cabinet height
- 36 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
- Cabinet width
- 20 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
- Cabinet depth
- 17 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 56°FManufacturer exact-part specification; no independent measurement.
- Duct connection
- YesManufacturer specification; no independent measurement.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- basement2,500–2,900 sq ft
Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 2,500–2,900 sq ft sizing range without identifying which conditions support its upper end.
PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
- Input power540 W
65°F · 60% RH · configuration not stated
Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.
PDF p.1 Electrical, Power · Santa Fe ↗ - Running current4.5 A
65°F · 60% RH · configuration not stated
Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.
PDF p.1 Electrical, Current Draw · Santa Fe ↗ - Sound level60 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer average sound value; distance, fan setting, duct state and air conditions are not specified.
Product Specifications, Average Sound Level · Santa-Fe ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Optional external pump · published lift
- 12 ft
Up to 12 ft vertical lift for optional external 4022220 pump kit; the base Classic is gravity drained.
Published specification · Santa Fe ↗ / Santa-Fe ↗ - Duct collar diameter
- 8 in.
Optional main return and supply duct collars are 8 in; the return hood also has an optional 6 in connection. The main 8 in return collar must be used.
Published specification · Santa Fe ↗
- Return and supply openings · airflow12 in.
At least 12 in is stated for air return/supply. The filter and front service panel must also be accessible; no separate numeric service clearance is given.
PDF p.3 Safety Instructions · Santa Fe ↗
Where it may fit
- A roomy basement installation with room for the 36 in vertical cabinet and service access.
Before you buy
- Check that the seller supplies the exact current part number and R454B generation shown here.
- Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.
The tradeoffs
- Capacity depends on inlet conditions; a rated floor area is not a guaranteed match for an unsealed or actively leaking space.
- The current minimum operating temperature is 56°F; lower-temperature product-family claims do not establish suitability below this exact-part limit.
Reviews & installation evidence
Current manufacturer product page, exact-part R454B specification and available current installation manual checked 2026-10-11. We have not independently tested this device.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer productSanta Fe Classic manufacturer product page
Santa-Fe · Checked Oct 12, 2026
- manufacturer specSanta Fe Classic 4044710 manufacturer specification TS-2107
Santa Fe · Checked Oct 12, 2026
- manufacturer manualSanta Fe TS-2095 04/26 Rev C installation and operation manual
Santa Fe · Checked Oct 12, 2026
Version: TS-2095 04/26 Rev C - manufacturer productSanta Fe Optional Condensate Pump Kit 4022220
Santa Fe · Checked Oct 12, 2026
Version: Manufacturer accessory listing checked 2026-10-12The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.