Documented model profile

Santa Fe Classic

The current R454B Classic 4044710 has a 36 in vertical cabinet and a 116 pint 80°F/60% RH rating, falling to 76 pints at 65°F/60% RH. It drains through a downward-sloped hose, with a separate optional pump for lift and optional duct kits for airflow distribution.

Model Classic / 4044710 · Current R454B part 4044710; TS-2095 04/26 Rev C
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
20 × 36 × 17 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Santa Fe Classic current manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
116 pints/day80°F / 60% RH
76 pints/day65°F / 60% RH
Drain arrangement
Gravity drainCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
Cabinet height
36 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet width
20 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet depth
17 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Depth including duct collars
Not verified
Minimum inlet-air temperature
56°FManufacturer exact-part specification; no independent measurement.
Duct connection
YesManufacturer specification; no independent measurement.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • basement2,500–2,900 sq ft

    Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment. The sheet gives a 2,500–2,900 sq ft sizing range without identifying which conditions support its upper end.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

  • Input power540 W

    65°F · 60% RH · configuration not stated

    Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

    PDF p.1 Electrical, Power · Santa Fe ↗
  • Running current4.5 A

    65°F · 60% RH · configuration not stated

    Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

    PDF p.1 Electrical, Current Draw · Santa Fe ↗
  • Sound level60 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Manufacturer average sound value; distance, fan setting, duct state and air conditions are not specified.

    Product Specifications, Average Sound Level · Santa-Fe ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
12 ft

Up to 12 ft vertical lift for optional external 4022220 pump kit; the base Classic is gravity drained.

Published specification · Santa Fe ↗ / Santa-Fe ↗
Duct collar diameter
8 in.

Optional main return and supply duct collars are 8 in; the return hood also has an optional 6 in connection. The main 8 in return collar must be used.

Published specification · Santa Fe ↗
  • Return and supply openings · airflow12 in.

    At least 12 in is stated for air return/supply. The filter and front service panel must also be accessible; no separate numeric service clearance is given.

    PDF p.3 Safety Instructions · Santa Fe ↗

Where it may fit

  • A roomy basement installation with room for the 36 in vertical cabinet and service access.

Before you buy

  • Check that the seller supplies the exact current part number and R454B generation shown here.
  • Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.

The tradeoffs

  • Capacity depends on inlet conditions; a rated floor area is not a guaranteed match for an unsealed or actively leaking space.
  • The current minimum operating temperature is 56°F; lower-temperature product-family claims do not establish suitability below this exact-part limit.

Reviews & installation evidence

Current manufacturer product page, exact-part R454B specification and available current installation manual checked 2026-10-11. We have not independently tested this device.

We are collecting relevant tests, installations and owner experience for this exact version.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer productSanta Fe Classic manufacturer product page

    Santa-Fe · Checked Oct 12, 2026

    Alternative source

  2. manufacturer specSanta Fe Classic 4044710 manufacturer specification TS-2107

    Santa Fe · Checked Oct 12, 2026

  3. manufacturer manualSanta Fe TS-2095 04/26 Rev C installation and operation manual

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2095 04/26 Rev C
  4. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.