Santa Fe Oasis105

The current R454B Oasis 1054044510 is rated 102 pints/day at 80°F/60% RH and 67 at 65°F/60% RH. Its 14.5 in horizontal cabinet supports optional ducting and a positive-pressure gravity drain that does not require a P-trap; lift needs a separate pump.

Model Oasis105 / 4044510 · Current R454B part 4044510; TS-2110 specification
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
24 × 14.5 × 16 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Santa Fe Oasis105 current manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
102 pints/day80°F / 60% RH
67 pints/day65°F / 60% RH
Drain arrangement
Gravity drainCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
Cabinet height
14.5 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet width
24 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet depth
16 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Depth including duct collars
Not verified
Minimum inlet-air temperature
49°FManufacturer exact-part specification; no independent measurement.
Noise measurement
Not verified
Duct connection
YesManufacturer specification; no independent measurement.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • crawl spaceUp to 3,300 sq ft

    Manufacturer sizing claim assumes a 5-foot ceiling. Water entry, air leakage and humidity still require assessment.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗
  • basementUp to 2,600 sq ft

    Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

  • Input power732 W

    65°F · 60% RH · configuration not stated

    Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

    PDF p.1 Electrical, Power · Santa Fe ↗
  • Running current6.1 A

    65°F · 60% RH · configuration not stated

    Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

    PDF p.1 Electrical, Current Draw · Santa Fe ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
12 ft

Compatible optional external 4022220 pump has up to 12 ft vertical lift. Positive-pressure gravity drain does not require a P-trap.

Published specification · Santa Fe ↗ / Santa-Fe ↗
Duct collar diameter
10 in.

Optional 10 in supply duct collar/plenum is sold separately; this record does not assert an exact return duct size.

Published specification · Santa Fe ↗
  • All around unit · airflow14 in.

    Text says 14 in around the unit; the same page diagram separately shows 6 in return and 14 in supply.

    PDF p.10 Basement/Crawl Space Installation paragraph 4 · Santa Fe ↗
  • Return-air opening · airflow6 in.

    Diagram shows 6 in return clearance, differing from 14 in all-around text and 12 in safety text.

    PDF p.10 Top-view location diagram · Santa Fe ↗
  • Supply-air opening · airflow14 in.

    Diagram shows 14 in clearance at the supply opening.

    PDF p.10 Top-view location diagram · Santa Fe ↗
  • Filter extraction side · filter removal2 in.

    At least 2 in for filter removal in the illustrated configuration; this is separate from airflow clearance.

    PDF p.10 Top-view location diagram · Santa Fe ↗
  • Return and supply openings · airflow12 in.

    Safety text asks for 12 in; p.10 gives a different detailed diagram and 14 in all-around text.

    PDF p.3 Safety Instructions · Santa Fe ↗

Same manual gives 12 in safety clearance,14 in all-around text and a 6 in return/14 in supply diagram. Manufacturer clarification is needed before using a tight layout.

Source discrepancy · Santa Fe ↗

Product page identifies 4044510 but its Manual link targets 4046590-IL TS2155. The 4044510 TS2093 document from Media Resources is used instead.

Source discrepancy · Santa-Fe ↗ / Santa Fe ↗

Where it may fit

  • A basement or crawl space where the 14.5 in cabinet, optional duct kit and filter service fit.

Before you buy

  • Check that the seller supplies the exact current part number and R454B generation shown here.
  • Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.

The tradeoffs

  • Capacity depends on inlet conditions; a rated floor area is not a guaranteed match for an unsealed or actively leaking space.
  • Older naming/category copy can imply 105 pints; the current 4044510 specification states 102 at 80°F/60% RH.

Reviews & installation evidence

Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.

Article · spec analysis

Oasis105 controls and why temperature changes the capacity figure

Earlier version / historical context: Oasis105 reviewed in March 2023; production part and refrigerant not identified

The article presents different capacity figures at warm, moderate and cool conditions, rather than treating 105 pints as a constant output. It explains floor, riser and hanging arrangements, optional room-to-room ducting and a controller with adjustable fan settings. The useful buying question is whether your location and control plan match that configuration, rather than whether the headline capacity sounds large enough.

Setting / method
Retailer review with condition-labelled tables and installation discussion. No raw test logs or identifiable test specimen.
What this does not prove
Historical retailer material with commercial interest. Do not transfer its controls, ratings or warranty terms to today’s SKU without the matching manual. Its savings and coverage claims are not validated here.
Read the original ↗

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer productSanta Fe Oasis105 manufacturer product page

    Santa-Fe · Checked Oct 12, 2026

    Alternative source

  2. manufacturer specSanta Fe Oasis105 4044510 manufacturer specification TS-2110

    Santa Fe · Checked Oct 12, 2026

  3. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.

    Alternative source

  4. manufacturer manualSanta Fe Oasis105 4044510 Installation Instructions

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2093 Rev C / 01.26

    Manufacturer media-resources manual identifies 4044510 on p.4. Its diagram shows return 6 inches, supply 14 inches and filter removal 2 inches; nearby text asks for 14 inches all around and safety text asks for 12 inches. The product page currently links a different 4046590-IL manual, which is not used here.

Show 1 more source
  1. retailerSylvane Reviews: The Santa Fe Oasis105 Dehumidifier

    Sylvane · Checked Oct 12, 2026

    Version: Oasis105 reviewed in March 2023; production part and refrigerant not identified

    External evidence; the summary identifies its scope and limits. Follow the original for the full account.