Documented model profile

Santa Fe UltraMD33

The current R454B UltraMD33 part 4044610 is a fixed in-wall unit with a 30 in-high, 5.75 in-deep cabinet and gravity drainage. It is specified for 37 pints/day at 80°F/60% RH. Wall framing, bezel dimensions, wiring and a downward-sloped drain determine the installation.

Model UltraMD33 / 4044610 · Current R454B part 4044610; TS-2091 04/26 Rev C
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
14.19 × 30 × 5.75 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
Santa Fe UltraMD33 current manufacturer product photograph

Product photograph: Santa Fe ↗

Check the essentials.

Extraction rating & conditions
37 pints/day80°F / 60% RH
22 pints/day65°F / 60% RH
Drain arrangement
Gravity drainCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
Cabinet height
30 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Cabinet width
14.1875 in.Exact specification 14.1875 in; product page rounds to 14.19 in. Front bezel is wider than the inner cabinet.
Cabinet depth
5.75 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
Depth including duct collars
Not verified
Minimum inlet-air temperature
49°FManufacturer exact-part specification; no independent measurement.
Duct connection
Not verifiedIn-wall device designed independently of HVAC; no supported duct-kit configuration confirmed in checked documentation.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • Manufacturer area statementUp to 1,200 sq ft

    Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.

    PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.

  • Input power260 W

    65°F · 60% RH · configuration not stated

    Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.

    PDF p.1 Electrical, Power · Santa Fe ↗
  • Running current2.2 A

    65°F · 60% RH · configuration not stated

    Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.

    PDF p.1 Electrical, Current Draw · Santa Fe ↗
  • Sound level46 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Current specification says 46 dBA; product page says 45 dBA. Measurement conditions and distance are not stated.

    PDF p.1 Specifications, Sound Rating · Santa Fe ↗
  • Sound level45 dBA

    temperature not stated · humidity not stated · configuration not stated · distance not stated

    Product page says 45 dBA, conflicting with 46 dBA current spec. Retain both as a source discrepancy, not two fan modes.

    Product Specifications, Average Sound Level · Santa-Fe ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
12 ft

Optional external 4022220 pump is rated up to 12 ft vertical lift; it is not built into UltraMD33.

Published specification · Santa Fe ↗ / Santa-Fe ↗
  • Cabinet to framing on each side · service0.13 in.

    Minimum 1/8 in spacing to framing on both sides; this is an in-wall fit requirement, not airflow clearance.

    PDF p.8 Installation Step 11 · Santa Fe ↗
  • Cabinet to rear wall · service0.5 in.

    Maintain 1/2 in behind the cabinet for alternate installations; normal 2 x 6 framing with 1/2 in drywall provides this gap.

    PDF p.8 Installation Step 11 · Santa Fe ↗
  • Existing blocking/headers to cabinet · service0.5 in.

    Existing blocking, headers and framing must not intrude into the opening and must remain at least 1/2 in from the cabinet.

    PDF p.8 Installation Step 11 · Santa Fe ↗

Install level or with 1–2° forward tilt; a backward tilt is not acceptable. Wall opening, drain route and access depend on 2 x 6,2 x 4-bezel or surface-mount configuration.

PDF p.8 Step 11 and tilt diagram · Santa Fe ↗

Current specification 46 dBA versus product page 45 dBA; distance/mode/conditions unknown. Do not average the numbers.

Source discrepancy · Santa Fe ↗ / Santa-Fe ↗

Where it may fit

  • A planned in-wall or supported surface-mount installation in a basement, apartment or other served area.

Before you buy

  • Check that the seller supplies the exact current part number and R454B generation shown here.
  • Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.
  • The 30 in cabinet is not a low crawl-space floor unit; check wall framing and the chosen bezel/surface kit.

The tradeoffs

  • Current specification says 22 pints at 65°F/60% RH, while product page labels the 22 pint point 73°F/60% RH.
  • Current spec 46 dBA and product page 45 dBA conflict, so the comparable noise value remains unknown.

Reviews & installation evidence

Current manufacturer product page, exact-part R454B specification and available current installation manual checked 2026-10-11. We have not independently tested this device.

We are collecting relevant tests, installations and owner experience for this exact version.

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualSanta Fe TS-2091 04/26 Rev C installation and operation manual

    Santa Fe · Checked Oct 12, 2026

    Version: TS-2091 04/26 Rev C
  2. manufacturer productSanta Fe UltraMD33 manufacturer product page

    Santa-Fe · Checked Oct 12, 2026

    Alternative source

  3. manufacturer specSanta Fe UltraMD33 4044610 manufacturer specification TS-2117

    Santa Fe · Checked Oct 12, 2026

  4. manufacturer productSanta Fe Optional Condensate Pump Kit 4022220

    Santa Fe · Checked Oct 12, 2026

    Version: Manufacturer accessory listing checked 2026-10-12

    The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.

    Alternative source