Documented model profile
Santa Fe UltraMD33
The current R454B UltraMD33 part 4044610 is a fixed in-wall unit with a 30 in-high, 5.75 in-deep cabinet and gravity drainage. It is specified for 37 pints/day at 80°F/60% RH. Wall framing, bezel dimensions, wiring and a downward-sloped drain determine the installation.
Model UltraMD33 / 4044610 · Current R454B part 4044610; TS-2091 04/26 Rev C
Checked Oct 12, 2026 · current

Product photograph: Santa Fe ↗
Check the essentials.
- Extraction rating & conditions
- 37 pints/day80°F / 60% RH22 pints/day65°F / 60% RH
- Drain arrangement
- Gravity drainCurrent manufacturer document specifies gravity drainage. An optional separate condensate pump provides lift; no built-in pump is documented.
- Cabinet height
- 30 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
- Cabinet width
- 14.1875 in.Exact specification 14.1875 in; product page rounds to 14.19 in. Front bezel is wider than the inner cabinet.
- Cabinet depth
- 5.75 in.Manufacturer exact-part specification; no independent measurement. Cabinet size does not include service, drain and any mounting/duct/accessory clearances.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 49°FManufacturer exact-part specification; no independent measurement.
- Duct connection
- Not verifiedIn-wall device designed independently of HVAC; no supported duct-kit configuration confirmed in checked documentation.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 1,200 sq ft
Manufacturer sizing claim assumes a 10-foot ceiling. Water entry, air leakage and humidity still require assessment.
PDF p.1 Sizing table and ceiling-height footnote · Santa Fe ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Input power260 W
65°F · 60% RH · configuration not stated
Manufacturer stated input watts at the listed air conditions; compressor duty cycle and annual consumption are not specified.
PDF p.1 Electrical, Power · Santa Fe ↗ - Running current2.2 A
65°F · 60% RH · configuration not stated
Manufacturer stated current at the listed air conditions; this is not starting current and is not converted into watts.
PDF p.1 Electrical, Current Draw · Santa Fe ↗ - Sound level46 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Current specification says 46 dBA; product page says 45 dBA. Measurement conditions and distance are not stated.
PDF p.1 Specifications, Sound Rating · Santa Fe ↗ - Sound level45 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Product page says 45 dBA, conflicting with 46 dBA current spec. Retain both as a source discrepancy, not two fan modes.
Product Specifications, Average Sound Level · Santa-Fe ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Optional external pump · published lift
- 12 ft
Optional external 4022220 pump is rated up to 12 ft vertical lift; it is not built into UltraMD33.
Published specification · Santa Fe ↗ / Santa-Fe ↗
- Cabinet to framing on each side · service0.13 in.
Minimum 1/8 in spacing to framing on both sides; this is an in-wall fit requirement, not airflow clearance.
PDF p.8 Installation Step 11 · Santa Fe ↗ - Cabinet to rear wall · service0.5 in.
Maintain 1/2 in behind the cabinet for alternate installations; normal 2 x 6 framing with 1/2 in drywall provides this gap.
PDF p.8 Installation Step 11 · Santa Fe ↗ - Existing blocking/headers to cabinet · service0.5 in.
Existing blocking, headers and framing must not intrude into the opening and must remain at least 1/2 in from the cabinet.
PDF p.8 Installation Step 11 · Santa Fe ↗
Install level or with 1–2° forward tilt; a backward tilt is not acceptable. Wall opening, drain route and access depend on 2 x 6,2 x 4-bezel or surface-mount configuration.
PDF p.8 Step 11 and tilt diagram · Santa Fe ↗Current specification 46 dBA versus product page 45 dBA; distance/mode/conditions unknown. Do not average the numbers.
Source discrepancy · Santa Fe ↗ / Santa-Fe ↗Where it may fit
- A planned in-wall or supported surface-mount installation in a basement, apartment or other served area.
Before you buy
- Check that the seller supplies the exact current part number and R454B generation shown here.
- Allow for the entire installation envelope, filter service, airflow, drain fittings and any separate pump.
- The 30 in cabinet is not a low crawl-space floor unit; check wall framing and the chosen bezel/surface kit.
The tradeoffs
- Current specification says 22 pints at 65°F/60% RH, while product page labels the 22 pint point 73°F/60% RH.
- Current spec 46 dBA and product page 45 dBA conflict, so the comparable noise value remains unknown.
Reviews & installation evidence
Current manufacturer product page, exact-part R454B specification and available current installation manual checked 2026-10-11. We have not independently tested this device.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer manualSanta Fe TS-2091 04/26 Rev C installation and operation manual
Santa Fe · Checked Oct 12, 2026
Version: TS-2091 04/26 Rev C - manufacturer productSanta Fe UltraMD33 manufacturer product page
Santa-Fe · Checked Oct 12, 2026
- manufacturer specSanta Fe UltraMD33 4044610 manufacturer specification TS-2117
Santa Fe · Checked Oct 12, 2026
- manufacturer productSanta Fe Optional Condensate Pump Kit 4022220
Santa Fe · Checked Oct 12, 2026
Version: Manufacturer accessory listing checked 2026-10-12The product page claims 12 ft vertical lift. Its linked June 2020 manual says not to exceed 15 ft; confirm the current kit and route rather than adopting the higher historical figure. The alternative source is that older manufacturer instruction sheet.