Documented model profile
AlorAir Sentinel HD35P
This 35-pint rated model provides manufacturer-described pump and gravity drainage modes. The pump may help when the drain is above the unit, but discharge height and the chosen mode need an installation check.
Model HD35P · SKU RF02ALOS-Sentinel-HD35P-0YDMW00 · Standard Sentinel HD35P, SKU RF02ALOS-Sentinel-HD35P-0YDMW00; R32 specification with file identifier 20260131
Checked Nov 22, 2026 · current
The standard HD35P listing identifies this SKU separately from the Wi-Fi version.

Check the essentials.
- Extraction rating & conditions
- 35 pints/day80°F / 60% RH · AHAM70 pints/dayTest conditions not verified
- Drain arrangement
- Built-in pumpPump and/or gravity mode as stated in the named product specification; mode and hose setup must be checked in the exact manual.
- Cabinet height
- 11.4 in.Manufacturer product specification; not independently measured.
- Cabinet width
- 11.2 in.Manufacturer product specification; not independently measured.
- Cabinet depth
- 15.2 in.Manufacturer product specification; not independently measured.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- 33°FManufacturer product specification; not independently measured.
- Power at published conditions
- Not verified
- Duct connection
- Not verified
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 1,000 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · AlorAir ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
Sources give different values or bounds without a complete shared test method. Check the exact version and document before relying on one figure.
- Running current2.9 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed current; test conditions and compressor starting current are not supplied. Wattage cannot be calculated from this value alone.
Product-page specification table: Current · AlorAir ↗ - Sound level50 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound claim; distance, acoustic test conditions and installation mode are not supplied.
Product-page specification table: Sound Pressure Level · AlorAir ↗ - Running current2.9 A
temperature not stated · humidity not stated · configuration not stated
Manufacturer-listed operating current at 115 V / 60 Hz. Load conditions and compressor start-up current are not stated; this is not a wattage measurement.
PDF p1, current/power specification row · AlorAir ↗ - Sound level< 50 dBA
temperature not stated · humidity not stated · configuration not stated · distance not stated
Manufacturer sound-pressure claim with its printed bound retained. Measurement distance, room conditions and ducted/unducted mode are not specified.
PDF p1, sound-pressure specification row · AlorAir ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Built-in pump · published lift
- 19.6 ft
AlorAir publishes a 19.6 ft vertical lift separately from the 19.6 ft supplied hose. Confirm usable lift for the actual route and delivered revision.
Published specification · AlorAir Crawlspace ↗ / AlorAir ↗ - Pump hose length
- 19.6 ft
Manufacturer lists a 19.6-foot pump/discharge line. Hose length and vertical pumping lift are separate specifications.
Published specification · AlorAir ↗
- 19.6 ft · The linked manual labels a vertical rise 19.6 ft, but does not establish the exact current R32 production revision.PDF p13 and p15, pump-discharge diagrams · AlorAir ↗
Where it may fit
- Comparing dedicated pump-equipped units for a sealed crawl space or basement.
Before you buy
- Confirm the exact current SKU, refrigerant generation and matching installation manual.
- Verify access clearance and the complete condensate-discharge route before ordering.
The tradeoffs
- The pump adds a component to maintain; the drain setup differs between pump and gravity operation.
Reviews & installation evidence
Manufacturer product-page and linked-document analysis checked 2026-10-11; no independent testing of performance, sound or reliability is claimed.
We are collecting relevant tests, installations and owner experience for this exact version.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer productAlorAir crawl-space, basement and whole-house catalog
AlorAir · Checked Oct 11, 2026
- manufacturer productAlorAir Sentinel HD35P manufacturer product page
AlorAir · Checked Oct 12, 2026
- manufacturer manualAlorAir Sentinel HD35P linked installation and operation manual
AlorAir · Checked Oct 12, 2026
Version: Linked manual, filename 20230810Exact model manual currently linked by the manufacturer; match the delivered model plate and document revision before installation.
- manufacturer productAlorAir Sentinel HD35P standard model listing
AlorAir Crawlspace · Checked Nov 22, 2026
Applies to the standard HD35P SKU on this page. Check the delivered manual and the complete route before installation.
Show 1 more source
- manufacturer specAlorAir Sentinel HD35P current linked specification sheet
AlorAir · Checked Nov 22, 2026
Version: File identifier 20260131