Documented model profile

AprilAire E070

The non-Wi-Fi E070 is listed for dedicated humidity control, with 70 pints/day at 80°F/60% RH and 53 at 73°F/60% RH in the current manufacturer reference guide. It drains to a floor/waste drain; measure cabinet and service space before selecting it.

Model E070 · Current listed non-Wi-Fi E-series model; exact refrigerant/manual revision unconfirmed.
Checked Oct 12, 2026 · current

Can I use it here?

Cabinet (W × H × D)
12.5 × 12.5 × 25 in.
Drain
Gravity drain
See prices, stores and buying notes ↓
AprilAire E070 manufacturer product photograph

Product photograph: AprilAire ↗

Check the essentials.

Extraction rating & conditions
70 pints/day80°F / 60% RH
53 pints/day73°F / 60% RH
Drain arrangement
Gravity drainExact product page describes hose/floor-drain use and no tray. Any pump needed for lift is a separate installation choice.
Cabinet height
12.5 in.Manufacturer specification; no independent measurement.
Cabinet width
12.5 in.Manufacturer specification; no independent measurement.
Cabinet depth
25 in.Manufacturer specification; no independent measurement.
Depth including duct collars
Not verified
Minimum inlet-air temperature
Not verified
Duct connection
YesManufacturer specification; no independent measurement.

Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓

Published floor-area claims

Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.

  • Manufacturer area statementUp to 2,200 sq ft

    Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.

    Exact model product description / specifications: floor area or Size for · AprilAire ↗

Power, current & sound

Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.

  • Running current5.4 A

    80°F · 60% RH · configuration not stated

    Manufacturer rated current at 80°F/60% RH inlet air and 0.0 external static pressure. This is current, not input watts or a starting-surge value.

    PDF p.1 Specifications, Current Draw and rating footnote · AprilAire ↗
  • Sound level53 dBA

    temperature not stated · humidity not stated · ducted · distance not stated

    Manufacturer sound rating for ducted installation. Distance, temperature, humidity and acoustic test method are not given; it is not an independent comparison.

    PDF p.1 Specifications, Noise row · AprilAire ↗
  • Standby power< 3 W

    temperature not stated · humidity not stated · standby

    Idle only: manufacturer says less than 3 W when both fan and compressor are stopped. This is not operating input power.

    PDF p.4 Operating the Dehumidifier / idle power · AprilAire ↗

Installation space & drain limits

These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.

Optional external pump · published lift
22 ft

Up to 22 feet lift for separately purchased AprilAire 4856 condensate pump. The base dehumidifier drains by gravity and does not contain this pump.

Published specification · AprilAire ↗
Duct collar diameter
8 in.

8-inch inlet and outlet connections. Duct length and static pressure limits still need the exact installation manual.

Published specification · AprilAire ↗
  • Filter extraction side · filter removal15 in.

    Keep at least 15 inches clear for the filter to slide out; leave the electrical/drain service panel accessible.

    PDF p.7 Figure 11 Filter Access Clearance · AprilAire ↗

Where it may fit

  • A dedicated humidity-control installation that fits the documented cabinet and gravity-drain route.

Before you buy

  • Check the exact model suffix and the installation envelope, including feet, duct collars, filter removal and the drain route.
  • Ask the seller or installer to confirm the current revision, included parts and warranty. Manufacturer listing directs buyers to Healthy Air Professionals.

The tradeoffs

  • Cabinet measurements do not include the full installation or filter-service envelope.

Reviews & installation evidence

Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.

Article · installation

E070 and E080 sizing: the crawl-space conditions an installer checks

Family context: Named E070/E080 family; article does not identify tested hardware revisions

This installer starts with encapsulation, air sealing, open vents and divided crawl-space areas before recommending E070 or E080. The distinction is useful: floor area describes the space, but does not describe all the incoming moisture or whether air can circulate between sections. Use the article as a checklist for an assessment, alongside the exact model manual and a measured installation plan.

Setting / method
Written installer explanation and commercial service recommendations; no instrumented side-by-side test.
What this does not prove
Service provider selling encapsulation and installation. Its square-foot rules and sound claims are not universal guarantees or independent test results.
Read the original ↗

Follow the evidence

Sources & further reading

Open the original material for the full context. A product specification is not an independent test.

  1. manufacturer manualAprilAire E070 Installation and Owner Manual

    AprilAire · Checked Oct 12, 2026

    Version: 10020790B / 02.24

    Exact non-W E070 installation manual hosted by AMG Air. Fifteen inches are needed for filter removal. It does not describe the E070 W control.

  2. manufacturer productAprilAire E070 manufacturer product page

    AprilAire · Checked Oct 12, 2026

  3. manufacturer specAprilAire E070 R32 Specification, Form 960

    AprilAire · Checked Oct 12, 2026

    Version: Form 960 / 320712 / 04.24

    Exact non-W E070 R32 specification hosted by Carrier Enterprise. Rated current is measured at 80°F/60% RH and zero external static pressure; sound has a ducted label but no distance.

  4. manufacturer specAprilAire all-products specification reference guide 2210

    AprilAire · Checked Oct 12, 2026

Show 1 more source
  1. installer reviewDehumidifier for Crawl Space

    Crawl Space Ninja · Checked Oct 12, 2026

    Version: Named E070/E080 family; article does not identify tested hardware revisions

    External evidence; the summary identifies its scope and limits. Follow the original for the full account.