Documented model profile
AprilAire E070
The non-Wi-Fi E070 is listed for dedicated humidity control, with 70 pints/day at 80°F/60% RH and 53 at 73°F/60% RH in the current manufacturer reference guide. It drains to a floor/waste drain; measure cabinet and service space before selecting it.
Model E070 · Current listed non-Wi-Fi E-series model; exact refrigerant/manual revision unconfirmed.
Checked Oct 12, 2026 · current

Product photograph: AprilAire ↗
Check the essentials.
- Extraction rating & conditions
- 70 pints/day80°F / 60% RH53 pints/day73°F / 60% RH
- Drain arrangement
- Gravity drainExact product page describes hose/floor-drain use and no tray. Any pump needed for lift is a separate installation choice.
- Cabinet height
- 12.5 in.Manufacturer specification; no independent measurement.
- Cabinet width
- 12.5 in.Manufacturer specification; no independent measurement.
- Cabinet depth
- 25 in.Manufacturer specification; no independent measurement.
- Depth including duct collars
- Not verified
- Minimum inlet-air temperature
- Not verified
- Duct connection
- YesManufacturer specification; no independent measurement.
Cabinet dimensions do not include airflow or service clearance. Follow the exact model manual. Check the source documents ↓
Published floor-area claims
Manufacturer sizing statements, kept with their ceiling and space assumptions. These are not measurements of your moisture load.
- Manufacturer area statementUp to 2,200 sq ft
Manufacturer area claim; ceiling height, leakage and humidity assumptions are not specified.
Exact model product description / specifications: floor area or Size for · AprilAire ↗
Power, current & sound
Published source readings, with their conditions. Amps are not converted into watts. Sound figures with different weighting, distance or duct configurations do not establish a quietness ranking.
- Running current5.4 A
80°F · 60% RH · configuration not stated
Manufacturer rated current at 80°F/60% RH inlet air and 0.0 external static pressure. This is current, not input watts or a starting-surge value.
PDF p.1 Specifications, Current Draw and rating footnote · AprilAire ↗ - Sound level53 dBA
temperature not stated · humidity not stated · ducted · distance not stated
Manufacturer sound rating for ducted installation. Distance, temperature, humidity and acoustic test method are not given; it is not an independent comparison.
PDF p.1 Specifications, Noise row · AprilAire ↗ - Standby power< 3 W
temperature not stated · humidity not stated · standby
Idle only: manufacturer says less than 3 W when both fan and compressor are stopped. This is not operating input power.
PDF p.4 Operating the Dehumidifier / idle power · AprilAire ↗
Installation space & drain limits
These are documented requirements and claims, not a complete fit calculation. Allow for fittings, hose routing, feet and access to remove the filter; follow the exact installation manual.
- Optional external pump · published lift
- 22 ft
Up to 22 feet lift for separately purchased AprilAire 4856 condensate pump. The base dehumidifier drains by gravity and does not contain this pump.
Published specification · AprilAire ↗ - Duct collar diameter
- 8 in.
8-inch inlet and outlet connections. Duct length and static pressure limits still need the exact installation manual.
Published specification · AprilAire ↗
- Filter extraction side · filter removal15 in.
Keep at least 15 inches clear for the filter to slide out; leave the electrical/drain service panel accessible.
PDF p.7 Figure 11 Filter Access Clearance · AprilAire ↗
Where it may fit
- A dedicated humidity-control installation that fits the documented cabinet and gravity-drain route.
Before you buy
- Check the exact model suffix and the installation envelope, including feet, duct collars, filter removal and the drain route.
- Ask the seller or installer to confirm the current revision, included parts and warranty. Manufacturer listing directs buyers to Healthy Air Professionals.
The tradeoffs
- Cabinet measurements do not include the full installation or filter-service envelope.
Reviews & installation evidence
Original summaries of external material. We did not perform these tests. The version and evidence limits below matter as much as the result.
Article · installation
E070 and E080 sizing: the crawl-space conditions an installer checks
Family context: Named E070/E080 family; article does not identify tested hardware revisions
This installer starts with encapsulation, air sealing, open vents and divided crawl-space areas before recommending E070 or E080. The distinction is useful: floor area describes the space, but does not describe all the incoming moisture or whether air can circulate between sections. Use the article as a checklist for an assessment, alongside the exact model manual and a measured installation plan.
- Setting / method
- Written installer explanation and commercial service recommendations; no instrumented side-by-side test.
- What this does not prove
- Service provider selling encapsulation and installation. Its square-foot rules and sound claims are not universal guarantees or independent test results.
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer manualAprilAire E070 Installation and Owner Manual
AprilAire · Checked Oct 12, 2026
Version: 10020790B / 02.24Exact non-W E070 installation manual hosted by AMG Air. Fifteen inches are needed for filter removal. It does not describe the E070 W control.
- manufacturer productAprilAire E070 manufacturer product page
AprilAire · Checked Oct 12, 2026
- manufacturer specAprilAire E070 R32 Specification, Form 960
AprilAire · Checked Oct 12, 2026
Version: Form 960 / 320712 / 04.24Exact non-W E070 R32 specification hosted by Carrier Enterprise. Rated current is measured at 80°F/60% RH and zero external static pressure; sound has a ducted label but no distance.
- manufacturer specAprilAire all-products specification reference guide 2210
AprilAire · Checked Oct 12, 2026
Show 1 more source
- installer reviewDehumidifier for Crawl Space
Crawl Space Ninja · Checked Oct 12, 2026
Version: Named E070/E080 family; article does not identify tested hardware revisionsExternal evidence; the summary identifies its scope and limits. Follow the original for the full account.