Abestorm Guardian SNS120
A pump-equipped 120-pint-rated Guardian intended for crawl spaces, basements and ducted whole-home installations. Current manufacturer sources disagree on cabinet dimensions and AHAM temperature, so verify the exact model drawing before sizing a tight installation.
- Cabinet height
- Not verified
- Drain arrangement
- built in pump
- Manufacturer lists whole home use.
- Built-in pump documented; check lift and hose limits.
- Duct connection documented; check collars and the approved layout.

AlorAir Sentinel HDi100
The HDi100 catalog separates a 100-pint AHAM rating from a 220-pint saturation claim. It uses pump drainage and a larger chassis than the smaller Sentinel units; the installed footprint and discharge route need checking.
- Cabinet height
- 17.9 in.
- Drain arrangement
- built in pump
- Manufacturer lists whole home use.
- Built-in pump documented; check lift and hose limits.
- Duct connection documented; check collars and the approved layout.

AlorAir Sentinel HDi120
A larger pump-equipped Sentinel model whose catalog lists 120 pints per day at AHAM and 235 pints at saturation. The manufacturer describes ductable use, but the appropriate kit and rated installation conditions still need verification.
- Cabinet height
- 17.9 in.
- Drain arrangement
- built in pump
- Manufacturer lists whole home use.
- Built-in pump documented; check lift and hose limits.
- Duct connection documented; check collars and the approved layout.
Why these conditions matter
Whole home models with a documented built-in pump, checked against duct connections are required; missing required facts are labeled separately. Compare the exact specifications and complete the manual-based installation checks before ordering.
Check the pump-equipped generation
Sentinel HD55P has documented built-in pumping for crawl spaces and basements. HD55S is a gravity-drain variant. Do not treat the shared HD55 name as proof of the same drain hardware.
Check the supporting sources ↓No confirmed candidate is useful information
If the selected installation has no confirmed model in our small catalog, keep that result visible. Missing cabinet or duct facts appear separately; a known mismatch does not. Change the arrangement or obtain the exact missing specification before ordering.
Do not infer an HVAC layout from a product label
The base AprilAire E080 and E100 document duct connections; Ultra70 also supports ducted arrangements. Connection support alone does not determine which HVAC layout is suitable.
Check the supporting sources ↓Ask for the complete installation plan
Record the air paths, humidity control, drain route and proposed service access. Have the installer check the exact manual before ordering collars, dampers or other accessories.
Checked Oct 11, 2026 · Installation checklist · Drain planning
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer productAbestorm Guardian SNS120 manufacturer product page
Abestorm · Checked Oct 11, 2026
Displayed SKU; top drainage feature paragraphs; i Specification table: AHAM, saturation, Unit Dimensions (L×W×H), Temperature Range, Sound Pressure Level, Refrigerant. SNS120 Product Description states duct compatibility.Capacity feature text says AHAM 120 at 73°F/60%; table says AHAM 120 at 80°F/60%. AHAM temperature is left null. Feature text mentions 36°F while table minimum is 33.8°F: minimum left null. Pump lift 14.7 ft is described while table Drain Height is slash.
- manufacturer specAbestorm Guardian SNS120 current linked specification sheet
Abestorm · Checked Oct 11, 2026
Version: Current product-page-linked PDF; filename revision 20173099Manufacturer specification table and application/ducting panel; compare with the exact product page and delivered model plate.Primary specification downloaded and checked. Filename date is a document identifier, not a verified publication date. Conflicting dimensions, generations and capacity conditions are retained in model notes.
- manufacturer productAlorAir crawl-space, basement and whole-house catalog
AlorAir · Checked Oct 11, 2026
Product-navigation and catalog sections: Crawl Space & Basement Dehumidifiers and Whole House Dehumidifiers. Capacity, drainage and dimensions per named model.Catalog navigation is reused on individual product pages. Some width/depth labels disagree with individual specification tables; no automatic reconciliation. Color variants and duplicate HDi90 ductable listing were excluded.
- manufacturer productAlorAir Sentinel HDi100 manufacturer product page
AlorAir · Checked Oct 11, 2026
Named model catalog card gives 100 PPD AHAM, 220 saturation and Pump Drainage; individual Specifications gives LxWxH, temperature and 60 dBA. Application includes basements and crawl spaces.Exact production part/SKU and manual revision not confirmed; recorded product-page model identity only. Manufacturer specifications are not independent test results.
- manufacturer specAlorAir Sentinel HDi100 current linked specification sheet
AlorAir · Checked Oct 11, 2026
Version: Current product-page-linked PDF; filename revision 20251219Manufacturer specification table and application/ducting panel; compare with the exact product page and delivered model plate.Primary specification downloaded and checked. Filename date is a document identifier, not a verified publication date. Conflicting dimensions, generations and capacity conditions are retained in model notes.
- manufacturer productAlorAir Sentinel HDi120 manufacturer product page
AlorAir · Checked Oct 11, 2026
Named model catalog card gives 120 PPD AHAM, 235 saturation and pump drainage; Application explicitly describes duct-able use; individual Specifications LxWxH and temperature.Exact production part/SKU and manual revision not confirmed; recorded product-page model identity only. Manufacturer specifications are not independent test results.
- manufacturer specAlorAir Sentinel HDi120 current linked specification sheet
AlorAir · Checked Oct 11, 2026
Version: Current product-page-linked PDF; filename revision 20251219Manufacturer specification table and application/ducting panel; compare with the exact product page and delivered model plate.Primary specification downloaded and checked. Filename date is a document identifier, not a verified publication date. Conflicting dimensions, generations and capacity conditions are retained in model notes.
- manufacturer productSentinel HD55P product details
AlorAir · Checked Oct 11, 2026
SKU RF02ALOS-Sentinel-HD55P-0YDMW00. Specification table: 55 pints at 80°F/60% RH, 120 at 90°F/90%; R32.Exact R32 SKU listing supplies the capacity and pump claim. Cabinet dimensions and operating range use the separately linked current R32 specification; do not transfer them from HD55S.
- manufacturer productSentinel HD55S White product details
AlorAir · Checked Oct 11, 2026
Product heading, specifications: R32, gravity drain, 19.2 × 12.2 × 13.3 inches, operating temperature.URL and some body copy use HD55, while heading names HD55S. Verify exact SKU before buying.
- manufacturer productE080 product details
AprilAire · Checked Oct 11, 2026
Product details and specification: base E080, dimensions, included duct collars and gravity drain setup.Capacity conditions are not identified here. Do not assume the 80-pint figure uses the same test conditions as another brand.
- manufacturer specSanta Fe Ultra70 4044100 Specification Sheet TS-2111 Rev B
Santa Fe · Checked Oct 11, 2026
Version: TS-2111 Rev B, 01/26PDF p1 table, drawing and footnoteTable footnote dimensions include collars; 22-inch body and 28-inch collared depth should be labelled separately. Ratings are manufacturer measurements, not our tests.