Whole-home dehumidifiers in a dedicated location for an external condensate pump
Selected: Whole home · Dedicated location; ducting undecided · External pump
Gravity-drain whole home candidates for dedicated location; ducting undecided, with a separately verified external condensate pump.
14 documented candidates
Compare specifications ↗Candidates match the selected documented conditions. Capacity, service access and accessory compatibility still need checking.
Select 2–10 candidates to compare their specifications.

AprilAire E070
The non-Wi-Fi E070 is listed for dedicated humidity control, with 70 pints/day at 80°F/60% RH and 53 at 73°F/60% RH in the current manufacturer reference guide. It drains to a floor/waste drain; measure cabinet and service space before selecting it.
- Cabinet height
- 12.5 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

AprilAire E080
A documented 80-pint option at 80°F / 60% RH, with duct support and gravity drainage. Its 15-inch cabinet excludes feet and duct collars.
- Cabinet height
- 15 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

AprilAire E080W
A R32 Wi-Fi dehumidifier with a 15 in cabinet for dedicated basement/crawl-space or whole-home ducted installations. The exact specification rates 80 pints/day at 80°F/60% RH and 65 at 73°F/60% RH. Gravity drainage is standard; pump lift requires an external accessory.
- Cabinet height
- 15 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

AprilAire E100
A documented 100-pint option at 80°F / 60% RH, with duct support and gravity drainage. Its 15-inch cabinet excludes feet and duct collars.
- Cabinet height
- 15 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

AprilAire E100W
A R32 Wi-Fi dehumidifier with a 15 in cabinet for dedicated basement/crawl-space or whole-home ducted installations. The exact specification rates 100 pints/day at 80°F/60% RH and 85 at 73°F/60% RH. Gravity drainage is standard; pump lift requires an external accessory.
- Cabinet height
- 15 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

AprilAire E130
The non-Wi-Fi E130 is listed for dedicated humidity control, with 130 pints/day at 80°F/60% RH and 105 at 73°F/60% RH in the current manufacturer reference guide. It drains to a floor/waste drain; measure cabinet and service space before selecting it.
- Cabinet height
- 18.75 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

AprilAire E130W
A R32 Wi-Fi dehumidifier with a 18.75 in cabinet for dedicated basement/crawl-space or whole-home ducted installations. The exact specification rates 130 pints/day at 80°F/60% RH and 105 at 73°F/60% RH. Gravity drainage is standard; pump lift requires an external accessory.
- Cabinet height
- 18.75 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Moiswell Marshal WD160
A ductable whole-home model with a fresh-air intake, convertible outlet and gravity drain. The manufacturer advertises 65 rated pints and 160 maximum pints but labels the rated standard inconsistently, so compare it cautiously.
- Cabinet height
- 21.46 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Santa Fe Ultra70
The Ultra70 adds a ducted whole-home use case to a low cabinet. It is deeper than the Compact70, so a height-only shortlist can miss an important installation constraint.
- Cabinet height
- 12 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Santa Fe Ultra V100
A current R454B ducted/ventilating whole-home dehumidifier, part 4047100, with 100 pints/day at 80°F/60% RH. It uses gravity drainage and needs room for ducting, service access and a P-trap; any condensate lift uses a separate pump.
- Cabinet height
- 24 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Santa Fe Ultra V125
A current R454B ducted/ventilating whole-home dehumidifier, part 4047200, with 125 pints/day at 80°F/60% RH. It uses gravity drainage and needs room for ducting, service access and a P-trap; any condensate lift uses a separate pump.
- Cabinet height
- 24 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Santa Fe Ultra V155
A current R454B ducted/ventilating whole-home dehumidifier, part 4047300, with 155 pints/day at 80°F/60% RH. It uses gravity drainage and needs room for ducting, service access and a P-trap; any condensate lift uses a separate pump.
- Cabinet height
- 24 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Santa Fe Ultra V205
A current R454B ducted/ventilating whole-home dehumidifier, part 4046180, with 205 pints/day at 80°F/60% RH. It uses gravity drainage and needs room for ducting, service access and a P-trap; any condensate lift uses a separate pump.
- Cabinet height
- 20.75 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.

Santa Fe UltraMD33
The current R454B UltraMD33 part 4044610 is a fixed in-wall unit with a 30 in-high, 5.75 in-deep cabinet and gravity drainage. It is specified for 37 pints/day at 80°F/60% RH. Wall framing, bezel dimensions, wiring and a downward-sloped drain determine the installation.
- Cabinet height
- 30 in.
- Drain arrangement
- gravity
- Manufacturer lists whole home use.
- Gravity drain documented; verify the complete drain route.
Why these conditions matter
Gravity-drain whole home candidates for dedicated location; ducting undecided, with a separately verified external condensate pump. Compare the exact specifications and complete the manual-based installation checks before ordering.
These units do not include the external pump
This list contains gravity-drain units for a proposed external-pump installation. The accessory is not included or automatically compatible. Check its inlet connection, flow, lift, controls and failure response against both manuals.
Plan the complete service arrangement
Keep the pump reservoir, hose route, electrical connection and any overflow or shutoff provision accessible. Ask the installer to specify the pump and the exact unit variant together, not as two unrelated purchases.
Check the supporting sources ↓Do not infer an HVAC layout from a product label
The base AprilAire E080 and E100 document duct connections; Ultra70 also supports ducted arrangements. Connection support alone does not determine which HVAC layout is suitable.
Check the supporting sources ↓Ask for the complete installation plan
Record the air paths, humidity control, drain route and proposed service access. Have the installer check the exact manual before ordering collars, dampers or other accessories.
Checked Oct 11, 2026 · Installation checklist · Drain planning
Follow the evidence
Sources & further reading
Open the original material for the full context. A product specification is not an independent test.
- manufacturer productAprilAire E070 manufacturer product page
AprilAire · Checked Oct 11, 2026
Product heading gives intended spaces and pints/day; Specifications: Actual Measurements H x W x D; Features / INCLUDED IN THE BOX / application describes drain route and duct collars.Current exact model listing checked 2026-10-11. Product gallery hero names the exact base or W model. Source directs buyers to Healthy Air Professionals; it is manufacturer information rather than a checkout offer.
- manufacturer productAprilAire E080W manufacturer product page
AprilAire · Checked Oct 11, 2026
Product heading gives intended spaces and pints/day; Specifications: Actual Measurements H x W x D; Features / INCLUDED IN THE BOX / application describes built-in Wi-Fi and ducted installation.Current exact model listing checked 2026-10-11. Product gallery hero names the exact base or W model. Source directs buyers to Healthy Air Professionals; it is manufacturer information rather than a checkout offer.
- manufacturer specAprilAire E080W specification Form 1014
AprilAire · Checked Oct 11, 2026
Version: Form 1014 • 324907 • 07.25Pages 1–2: model-specific R32 specifications, capacity conditions, cabinet dimensions, inlet operating limits, floor/waste drain, optional external 4856 pump and duct collars.Manufacturer-authored exact-model PDF. Some copies hosted by distributors. Capacity at 0.0ESP; dimensions exclude adjustable feet, filter doors/user interface and duct collars; noise listed for ducted installation. Source checked 2026-10-11.
- manufacturer productAprilAire E100W manufacturer product page
AprilAire · Checked Oct 11, 2026
Product heading gives intended spaces and pints/day; Specifications: Actual Measurements H x W x D; Features / INCLUDED IN THE BOX / application describes built-in Wi-Fi and ducted installation.Current exact model listing checked 2026-10-11. Product gallery hero names the exact base or W model. Source directs buyers to Healthy Air Professionals; it is manufacturer information rather than a checkout offer.
- manufacturer specAprilAire E100W specification Form 1015
AprilAire · Checked Oct 11, 2026
Version: Form 1015 • 326014 • 07.25Pages 1–2: model-specific R32 specifications, capacity conditions, cabinet dimensions, inlet operating limits, floor/waste drain, optional external 4856 pump and duct collars.Manufacturer-authored exact-model PDF. Some copies hosted by distributors. Capacity at 0.0ESP; dimensions exclude adjustable feet, filter doors/user interface and duct collars; noise listed for ducted installation. Source checked 2026-10-11.
- manufacturer productAprilAire E130 manufacturer product page
AprilAire · Checked Oct 11, 2026
Product heading gives intended spaces and pints/day; Specifications: Actual Measurements H x W x D; Features / INCLUDED IN THE BOX / application describes drain route and duct collars.Current exact model listing checked 2026-10-11. Product gallery hero names the exact base or W model. Source directs buyers to Healthy Air Professionals; it is manufacturer information rather than a checkout offer.
- manufacturer productAprilAire E130W manufacturer product page
AprilAire · Checked Oct 11, 2026
Product heading gives intended spaces and pints/day; Specifications: Actual Measurements H x W x D; Features / INCLUDED IN THE BOX / application describes built-in Wi-Fi and ducted installation.Current exact model listing checked 2026-10-11. Product gallery hero names the exact base or W model. Source directs buyers to Healthy Air Professionals; it is manufacturer information rather than a checkout offer.
- manufacturer specAprilAire E130W specification Form 1023
AprilAire · Checked Oct 11, 2026
Version: Form 1023 • 325649 • 06.25Pages 1–2: model-specific R32 specifications, capacity conditions, cabinet dimensions, inlet operating limits, floor/waste drain, optional external 4856 pump and duct collars.Manufacturer-authored exact-model PDF. Some copies hosted by distributors. Capacity at 0.0ESP; dimensions exclude adjustable feet, filter doors/user interface and duct collars; noise listed for ducted installation. Source checked 2026-10-11.
- manufacturer productMoiswell Marshal WD160 manufacturer product page
Moiswell · Checked Oct 11, 2026
Version: Marshal WD160 current listingExact SKU, Description duct/HVAC/fresh-air paragraphs; auto gravity/external pump headings; Specifications65/160PPD and D/W/H14.88/24.72/21.46in; exact embedded product object and main gallery.Description 65 PPD@DOE conflicts with table 65 PPD(AHAM). Keep standard and conditions null. Drain is gravity; external pump shown separately, not built in.
- manufacturer manualSanta Fe TS-2091 04/26 Rev C installation and operation manual
Santa Fe · Checked Oct 11, 2026
Version: TS-2091 04/26 Rev CDrain Installation Considerations page 5: downward-sloped hose, optional external pump and code-dependent drain connection.Exact current part-number document. External pump is optional, not built in. Advance Dry 110 TS2135 includes apparent Advance Dry 100 naming typos in drainage text; cover/registrations identify 4047010.
- manufacturer productSanta Fe Ultra V100 manufacturer product page
Santa-Fe · Checked Oct 11, 2026
Manufacturer page readable via web retrieval; automated local HTTP requests return 403. Exact current manufacturer specification PDF is the fallback.
Ideal Applications; Product Specifications: Part Number, Pint Capacity, Power with stated temperature/RH, Operating Temperature, Performance At, Unit Dimensions; ducting and control features.Current part number is used as generation identity. Older R410A/R134A data and legacy category descriptions are not merged. Current product page is not an independent test; complete drain installation remains to be checked from its matching manual. Rechecked exact current part 2026-10-11; conflicting figures are retained in field notes and buying checks.
- manufacturer productSanta Fe Ultra V125 manufacturer product page
Santa-Fe · Checked Oct 11, 2026
Manufacturer page readable via web retrieval; automated local HTTP requests return 403. Exact current manufacturer specification PDF is the fallback.
Ideal Applications; Product Specifications: Part Number, Pint Capacity, Power with stated temperature/RH, Operating Temperature, Performance At, Unit Dimensions; ducting and control features.Current part number is used as generation identity. Older R410A/R134A data and legacy category descriptions are not merged. Current product page is not an independent test; complete drain installation remains to be checked from its matching manual. Rechecked exact current part 2026-10-11; conflicting figures are retained in field notes and buying checks.
- manufacturer productSanta Fe Ultra V155 manufacturer product page
Santa-Fe · Checked Oct 11, 2026
Manufacturer page readable via web retrieval; automated local HTTP requests return 403. Exact current manufacturer specification PDF is the fallback.
Ideal Applications; Product Specifications: Part Number, Pint Capacity, Power with stated temperature/RH, Operating Temperature, Performance At, Unit Dimensions; ducting and control features.Current part number is used as generation identity. Older R410A/R134A data and legacy category descriptions are not merged. Current product page is not an independent test; complete drain installation remains to be checked from its matching manual. Rechecked exact current part 2026-10-11; conflicting figures are retained in field notes and buying checks.
- manufacturer productSanta Fe Ultra V205 manufacturer product page
Santa-Fe · Checked Oct 11, 2026
Manufacturer page readable via web retrieval; automated local HTTP requests return 403. Exact current manufacturer specification PDF is the fallback.
Ideal Applications; Product Specifications: Part Number, Pint Capacity, Power with stated temperature/RH, Operating Temperature, Performance At, Unit Dimensions; ducting and control features.Current part number is used as generation identity. Older R410A/R134A data and legacy category descriptions are not merged. Current product page is not an independent test; complete drain installation remains to be checked from its matching manual. Rechecked exact current part 2026-10-11; conflicting figures are retained in field notes and buying checks.
- manufacturer productSanta Fe UltraMD33 manufacturer product page
Santa-Fe · Checked Oct 11, 2026
Manufacturer page readable via web retrieval; automated local HTTP requests return 403. Exact current manufacturer specification PDF is the fallback.
Ideal Applications; Product Specifications: Part Number, Pint Capacity, Power with stated temperature/RH, Operating Temperature, Performance At, Unit Dimensions; ducting and control features.Current part number is used as generation identity. Older R410A/R134A data and legacy category descriptions are not merged. Current product page is not an independent test; complete drain installation remains to be checked from its matching manual. Rechecked exact current part 2026-10-11; conflicting figures are retained in field notes and buying checks.
- manufacturer specSanta Fe UltraMD33 4044610 manufacturer specification TS-2117
Santa Fe · Checked Oct 11, 2026
Version: Current R454B exact-part specification asset checked 2026-10-11First page: exact model/part number, capacity with conditions, dimensions, power, temperature and drain. First-page embedded manufacturer photograph is extracted for editorial identification.Current manufacturer media-resource library points to this exact-part PDF. Dimensions exclude service access. Source notes about collared/uncollared dimensions and other conflicts appear in the model record.
- manufacturer manualSanta Fe TS-2157 04/26 Rev H installation and operation manual
Santa Fe · Checked Oct 11, 2026
Version: TS-2157 04/26 Rev HDrain Installation page 12; registrations page 4 gives all three exact part numbers; location page 5 requires 6.75 in elevation for a P-trap.Exact current part-number document. External pump is optional, not built in. Advance Dry 110 TS2135 includes apparent Advance Dry 100 naming typos in drainage text; cover/registrations identify 4047010.
- manufacturer manualSanta Fe TS-2125 04/26 Rev C installation and operation manual
Santa Fe · Checked Oct 11, 2026
Version: TS-2125 04/26 Rev CDrain Installation page 10; unit requires 6.75 in elevation for a P-trap and optional external pump.Exact current part-number document. External pump is optional, not built in. Advance Dry 110 TS2135 includes apparent Advance Dry 100 naming typos in drainage text; cover/registrations identify 4047010.
- manufacturer manualSanta Fe Ultra70 Installation & Operation Instructions
Santa Fe / Therma-Stor · Checked Oct 11, 2026
Version: TS-2082 04/26 Rev C; part 4044100Printed pages 4, 8 and 10–15: registration, drainage and alternative duct layouts.Exact 4044100 instructions, TS-2082 Rev C 04/26. Working official digital-asset link replaces the access-blocked product-site PDF.
- manufacturer productSentinel HD55P product details
AlorAir · Checked Oct 11, 2026
SKU RF02ALOS-Sentinel-HD55P-0YDMW00. Specification table: 55 pints at 80°F/60% RH, 120 at 90°F/90%; R32.Exact R32 SKU listing supplies the capacity and pump claim. Cabinet dimensions and operating range use the separately linked current R32 specification; do not transfer them from HD55S.
- manufacturer productE080 product details
AprilAire · Checked Oct 11, 2026
Product details and specification: base E080, dimensions, included duct collars and gravity drain setup.Capacity conditions are not identified here. Do not assume the 80-pint figure uses the same test conditions as another brand.
- manufacturer productE100 product details
AprilAire · Checked Oct 11, 2026
Product details: base E100, 15 × 14 × 26 inches, duct collars and drain setup.Capacity test conditions not verified from this page.
- manufacturer specSanta Fe Ultra70 4044100 Specification Sheet TS-2111 Rev B
Santa Fe · Checked Oct 11, 2026
Version: TS-2111 Rev B, 01/26PDF p1 table, drawing and footnoteTable footnote dimensions include collars; 22-inch body and 28-inch collared depth should be labelled separately. Ratings are manufacturer measurements, not our tests.